1

2

3

4

5

L

6

N–

7

Z

A E/X

a

b

LT

Mot. a

Mot. b

MOT

VLD 51/038 -BSY+

7

1

8

2

9

3

10

4

11

5

12

6

(WH)

(BN)

(OG)

(YE)

(GN)

Mot. a

Mot. b

HS

Data a

Data b

(BK)

(BK)

(OG)

2x47k

W

Junction box /
Caja de conexión

EM 47 K

(WH)

(BN)

(OG)

(YE)

(GN)

Mot. a

Mot. b

HS

Data a

Data b

Connection / Conexión

Connection via junction box /
Conexión a través de caja de conexión

Further window drives can be
parallel connected /
Se pueden conectar en paralelo 
varios motores  

Monitoring  /

Supervisión *

VP signal of connected BSY+ window drives has 
to be activated /
Debe activarse la señal VP de los actuadores de 
apertura BSY+ conectados

BSY+ Drive(s) / motor

Group / Grupo

1 2 3 4 5 6

7 8 9 10 11 12

Endmodul

Terminal module

Module terminal

Connection / Conexión

(OG)

(BK)

(BK)

2x47k

W

Junction box /
Caja de conexión

1

2

3

4

5

L

6

N–

7

Z

A E/X

a

b

LT
Group / Grupo

 

Monitoring  /

Supervisión *

Mot. a

Mot. b

MOT

VLD 51/038 -BSY+ 

BSY+ Drive(s) / Motor

7

1

8

2

9

3

10

4

11

5

12

6

(WH)

(WH)

(BN)

(BN)

(OG)

(OG)

(YE)

(YE)

(GN)

(GN)

Mot. a

Mot. a

Mot. b

Mot. b

HS

HS

Data a

Data a

Data b

Data b

EM 47 K

BSY+ drive directly connected to WLC /
Actuador de ventana BSY+ directamente conectado al WLC

Loop through terminals /
Bornes de enlazado 
max. 60 V / 6 A

VP signal of connected BSY+ window drives 
has to be activated /
Debe activarse la señal VP de los 
actuadores de apertura BSY+ conectados

(WH)  white 

/  blanco

(BN)  brown  /  marrón
(OG)  orange  /  naranja
(BK)  black  

/  negro

(YE)  yellow  /  amarillo
(GN)  green 

/  verde

(GY)  grey 

/  gris

Protect against short circuit /
Proteger contra cortacircuitos

1 2 3 4 5 6

7 8 9 10 11 12

Endmodul

T erminal module

Module terminal

*  not in case of /
  no en el caso
  GVL 8xxx-E/ -K/ -M

*  not in case of /
  no en el caso
  GVL 8xxx-E/ -K/ -M

Summary of Contents for VLD 51/038-BSY+

Page 1: ...824 37 2 1 10 15 E 222052 C US en Original instructions Page 2 es Manual original P gina 6 VLD 51 038 BSY PI VLD Please order bracket sets separately Rogamos que pidan los juegos de fijaci n por separ...

Page 2: ...connected to a Class 2 power supply For NorthAmerica 15 The Uniform Building Code Standard Vols 1 2 3 have to be observed The VLD 51 038 can be integrated in almost all common profiles Please consult...

Page 3: ...75 19mm 19mm 19mm 19mm 3 OFF ON 1 23 4 English 3 12 99 824 37 2 1 10 15 1 2 3 4 5 6 7 8 9 10 11 12 Mot a Mot b HS Data a Data b Signal WH Mot a BN Mot b OG HS YE Data a GN Data b Signal Clamping range...

Page 4: ...tch the window will be locked again For further information contact your D H service and sales partner Service position VLD 51 038 BSY 6 12 service position control plus Triggering of a single window...

Page 5: ...when mounting and starting has been carried out by an authorized D H distributor D H guarantee is expired with connection of D H components with external systems or with mixing of D H products with p...

Page 6: ...comprobaci nfinaldelproducto 14 Elactuadorhadeconectarseaunafuentedealimentaci ndeclase2 ParaEstadosUnidosdeAm rica 15 Sedeber ntenerencuentalosvol menes1 2y3delosEst ndaresUniformesdelC digoT cnicode...

Page 7: ...38 mm 1 49 Modo de servicio bascular antes de girar carrera de cierre 19 mm 0 75 19mm 19mm 19mm 19mm 3 Cable tie Sujetacables max 7 mm 0 28 rea de bornes 28 18 AWG unifilar o con hilos conductores fin...

Page 8: ...ci n de varias ventanas 1 Ventana 2 Ventana Con la entrada de posici n de servicio el WLC se desplaza hacia la posici n de giro de la ventana Para la alimentaci n de corriente el actuador debe activar...

Page 9: ...rios y embalajes sean sometidos a un proceso de recuperaci n que respete el medio ambiente No arroje las herramientas el ctricas a la basura S lo para los pa ses de la UE Conforme a la Directriz Europ...

Page 10: ...Connection Conexi n Connection via junction box Conexi n a trav s de caja de conexi n Further window drives can be parallel connected Se pueden conectar en paralelo varios motores Monitoring Supervisi...

Page 11: ...ive directly connected to WLC Actuador de ventana BSY directamente conectado al WLC Loop through terminals Bornes de enlazado max 60 V 6 A VP signal of connected BSY window drives has to be activated...

Page 12: ...7 4 9 3 All sizes in millimetre Todas las medidas en mil metros D H MechatronicAG Georg Sasse Str 28 32 Germany 22949Ammersbek 49 239 Tel 40 605 65 49 Fax 40 605 65 254 E Mail info dh partner com www...

Reviews: