background image

(BN)  braun 

/  brown  /  brun  

/  marrón

(BK)  schwarz /  black 

/  noir 

/  negro

(BU)  blau 

/  blue 

/  bleu 

/  azul

(YE)  gelb 

/  yellow  /  jaune 

/  amarillo

(GN)  grün 

/  green 

/  vert  

/  verde

(WH)  weiss 

/  white 

/  blanc   /  blanco

(PK)  rosa 

/  pink 

/  rose  

/  rosa

(GR)  grau 

/  grey 

/  gris  

/  gris

Aderbelegung Stecker / Pin Assigment / Brochage des fiches / Asignación de cables

DE / EN / FR / ES

DE / EN / FR / ES

99.831.10 1.3/01/23

99.831.10 1.3/01/23

14/16

15/16

VCD 204 -K

VCD 204 -K

BN (n.c.)

 

YE (n.c.)

 

GN (SKS)

 

WH (SKS)

 

-SKS

 

BN (n.c.)

 

YE (n.c.)

 

GN (SGI)

 

WH (SGI)

 

-SGI

 

Anschluss / Connection / Connexion  / Conexión

Abzweigdose / Junction box / 
Boîte de dérivation / Caja de conexión

VCD 204 -K

 

L

N

PE

(BU)

 

(YE/GN)

 

(BN)

 

N

PE

L

(BK)

 

L

230 VAC
50 ... 60 Hz

L+N nicht vertauschen! PE anschließen! /
Do not reverse L+N! Connect PE! /
Ne pas intervertir L+N ! Raccorder PE ! /
¡No confundir L+N! ¡Conectar la puesta a tierra! 

230 V AC

50 ... 60 Hz

24 

V DC

Netzanschluss /
mains supply /
Raccord secteur /
Conexión a la red

Optionale Meldungen /
Optional signals /
Signals optional /
Señales opcional

s

r

BN (n.c.)

 

GN

WH

YE

-SA-SZ

 

ма

x

. 50 

V

/0,5 А

 

BN (L      )

 

BK (L      )

 

YE/GN (     )

 

BU (N)

 

30 

m

m

41,2 

m

m

480 

m

m

47 

m

m

240 mm

240 mm

Abmessungen / Dimensions / Dimensions / Dimensión

Summary of Contents for VCD 204-K

Page 1: ...gamos que pidan los juegos de fijaci n por separado D H Downloads de Originalbetriebsanleitung Seite 2 Anschluss Seite 14 Abmessungen Seite 15 en Original instructions Page 5 Connection Page 14 Dimens...

Page 2: ...Daten mit denen dieses Produkt versehen ist Vers umnisse bei der Einhaltung der nachfolgenden Anweisungen k nnen elektrischen Schlag Brand und oder schwere Verletzungen verursachen Bewahren Sie alle...

Page 3: ...gt der Antrieb ber einen aktiven Schutz f r die Hauptschlie kante Bei einer berlast im Schlie bereich 3 und 2 f hrt der Antrieb f r 20 Sekunden wieder AUF Danach f hrt der Antrieb wieder ZU Sollte na...

Page 4: ...die Fahrt unterbrochen worden sein oder derAntrieb wieder auf maximale Hubl nge gebracht werden muss wieder mit Punkt 1 begonnen werden STOP 3 Am Antrieb muss in ZU Richtung weiter Spannung anliegen M...

Page 5: ...ized condition Inspection and maintenance has to be carried out according to D H maintenance notes Only original D H spare parts may be used RepairistobecarriedoutexclusivelybyD H Wipe away debris or...

Page 6: ...dge protection In the CLOSE direction the drive has an active protection for the main closing edge If there is an overload in the closing ranges 3 and 2 the drive runs OPEN for 20 seconds then CLOSE a...

Page 7: ...you hear a pulsating ton The drive is now in learning mode The magnet can now be removed and the drive no longer has to be under voltage Close drive 1 Allow the drive to run OPEN until you reach the...

Page 8: ...es d origine D H non modifi es Observer les instructions de montage du kit de console Respecter les indications figurant sur la notice de s curit rouge ci jointe Motorisation avec c ble PVC de 2 5 m E...

Page 9: ...e accessible aux mains Ar te de fermeture principale Ar te de fermeture lat rale Ar te de fermeture lat rale Toutes les forces env 20 de r serve de coupure En peu de temps P l a g e s d e f e r m e t...

Page 10: ...apr s un signal sonore le moteur est d sormais en mode d entra nement L aimant peut tre retir et la tension ne doit plus tre appliqu e au moteur Rentrer le moteur 1 Faire tourner le moteur dans le se...

Page 11: ...ensoresde lluvia Emplear nicamente piezas originales D H no modificadas Observar las instrucciones de montaje del juego de fijaciones Respetar las indicaciones de la hoja de serguridad adjunta Motor c...

Page 12: ...rea accesible para las manos Canto de cierre principal Canto de cierre secundario Canto de cierre secundario Tipo VCD 204 K Alimentaci n 230 VAC 10 15 50 60 Hz Rendimiento 10 W 15 VA Fuerza nominal 2...

Page 13: ...amiento est ahora en el modo de aprendizaje Puede retirarse el im n y no debe haber m s tensi n en el accionamiento Cerrar el accionamiento 1 Dejar que se desplace el accionamiento en la direcci n ABR...

Page 14: ...BN n c YE n c GN SGI WH SGI SGI Anschluss Connection Connexion Conexi n Abzweigdose Junction box Bo te de d rivation Caja de conexi n VCD 204 K L N PE BU YE GN BN N PE L BK L 230 VAC 50 60 Hz L N nic...

Page 15: ...DE EN FR ES 99 831 10 1 3 01 23 15 16 VCD 204 K 30 mm 4 1 2 m m 480 mm 4 7 m m 240 mm 240 mm Abmessungen Dimensions Dimensions Dimensi n...

Page 16: ...o dh partner com www dh partner com 2013 D H Mechatronic AG Ammersbek Technische nderungen vorbehalten Rights to technical modifications reserved Sous r serve de modifications techniques Derecho reser...

Reviews: