Mount the drives mechanical stress-free.
With that, a better load distribution is ensured on all
the drives.
Mounting informations
English
English
99.831.12 1.0/08/13
99.831.12 1.0/08/13
6/16
7/16
VCD 204 -K
VCD 204 -K
Type
VCD 204 -K-TMS+ Set
Power supply
230 V AC / +10...-15 %
Power consumption
22 W / 30 VA
Nominal locking force
approx. 2x 2000 N (Excluding bracket)
Service life
>10 000 double strokes
Duty cycle
30 % (With cycle time 10 minutes)
Housing
Zinc-diecasting, powdercoated
Ingress protection
IP 30
Temp. range
0 ... +60 °C
Nominal stroke length*
See type plate
Additional functions
Closing edge protection activated (3 stroke repeatings), Locking relief activted
* Adjustable with magnet
Nominal force
2x 200 N
Technical data
All approx. 20 % switch-off reserve (temporary)
Running speed and forces
Closure Ranges
~6 mm/s
150 N
(Safety cut-off force)
5 mm/s
150 N
77 mm
~6 mm/s
200 N
23 mm
Closing edge protection
In the "CLOSE" direction the drive set has an active
protection for the main closing edge. If there is an
overload in the closing ranges 3 and 2, the drives run
"OPEN" for 20 seconds, then "CLOSE" again. If
closing is not possible after three attempts, the
drives remain in this position.
In addition, the drives are equipped with passive
protection. The closing speed in closing range 2 and
1 is reduced to 5 mm/s.
Significantly greater forces can be
exerted at the secondary closing edges.
Danger of crushing hands and fingers!
Main closing edge
Secondary closing edge
Secondary closing edge
Voltage must continue to
be applied to the drives when
moving in the “CLOSE”
direction.
Hold the magnet next
to the drive (...-B) as shown in the
diagramme (2 sec.) until you hear
a pulsating ton >
The
drives
are
now
in
learning
mode
.
The
magnet
can
now
be
removed
and
the
drive
no
longer
has
to
be
under
voltage
.
Stroke limiting with magnets
Close drives.
1
Allow the drives to run
“OPEN” until you reach the
required stroke.
If the stroke is set incorrectly,
the procedure is accidentally
interrupted or the drives
continues to the full stroke
length, please return to point 1
and start again.
3
appr
.100 mm
learning mode
appr. 2 sec.
2
B
oth drives must be electrically connected in order to set the stroke.
Only one drive needs to be switched to the stroke learning mode with the magnet.
VCD 204-K-TMS-B
24 VDC
230 V
AC
STOP