D+H RZN 43-E Series Instructions For Use Manual Download Page 3

OK

RZN 43xx-E

3/16

99.821.70 3.5/01/12

GKS

567

566

NBE

N+

24V=

VE

530

Service

USB/PC

F3,15A

F1,25A

F0,125A

Motherboard

1 2 3 4 5

6 7

N

-

N

+

S

S

t

-

S

A

L

+

K

Z

Z

E1

1 2 3 4 5

6 7

N

-

N

+

S

S

t

-

S

A

L

+

K

Z

Z

E2

1 2 3 4 5

6 7

1 2 3 4 5

6 7

1 2 3 4 5

6 7

1 2 3 4 5

6 7

1 2 3 4 5

6 7

1 2 3 4 5

6 7

8 9 10 11

8 9 10 11

8 9 10 11

8 9 10 11

8 9 10 11

8 9 10 11

Bez.:

Bez.:

Bez.:

Bez.:

Bez.:

Bez.:

Bez.:

Bez.:

Bez.:

Bez.:

Bez.:

Bez.:

GK

VE

Trafo

Trafo

+

+B

-

ERDA

E3

E4

optional functional extension by modules

slots E1 and E2

earthing

optional functional extension by modules

for extension of control panel

(ribbon cable required)

fire recognition

element

(thermal maximum

detector) *

free slots for LE/ GE/ WE/ AE/ SE 622

battery

connection

rectifier card GK

power supply

plug-in unit VE

* Monitoring the inner temperature of the controller. An emergency opening of the complete smoke and heat

ventilation system, under alarm conditions, will occur if the inner temperature exceeds 72°C, caused by the radiant
heat from a fire in the immediate vicinity of the installation location.

VE

530

Service

USB/PC

F3,15A

F1,25A

F0,125A

Rectifier card GK

1 x per control panel

2 x per control panel

up to an overall power of 32A
or

up to an total current of 64A
(2 motherboards).

Supply plug-in card
VE 520 / VE 530

1 x per control panel

Monitoring of
- grid
- battery voltage
- battery charging voltage
- earth leakage protection.

Stabilization GKS 567 *

to stabilize the output voltage when
connecting an external drive.

Output current

:

16A

Output voltage

:

24VDC ±10%

Residual ripple

:

10%

Mains-battery-plug-in unit NBE 566

Stabilization GPS 566/32 *

to stabilize the output voltage when
connecting an external drive.

Output current

:

32A

Output voltage

:

24VDC ±10%

Residual ripple

:

10%

Stabilization GPS 566/64 *

to stabilize the output voltage when
connecting an external drive.

Output current

:

64A

Output voltage

:

24VDC ±10%

Residual ripple

:

10%

General plug-in

Summary of Contents for RZN 43-E Series

Page 1: ...nstallation commissioning repair and service The highest national and international quality standards are therefore reliably fulfilled The comprehensive network of D H service and sales partners is at...

Page 2: ...d by D H for carrying out this maintenance competently and will be automatically provided with the latest maintenance instructions Following tests must be carried out during maintenance External exami...

Page 3: ...heat ventilation system under alarm conditions will occur if the inner temperature exceeds 72 C caused by the radiant heat from a fire in the immediate vicinity of the installation location VE 530 Se...

Page 4: ...er power lines In case of a cable with green yellow this must Cable and terminal boxes have to be labeled ground wire not be used Slot E1 E2 AM 44 Z Alarm cutoff module TR 42 Cutoff relay module WFR 4...

Page 5: ...function can be deactivated via the servicetool Attention Reset of the service timer can be carried out by a specialist company only who has been authorized by the appliance manufacturer close red gre...

Page 6: ...switched OFF ON for Smoke Detector Reset at the control panel This line is released by a line connected in series Every previous plug in slot after the releasing line must be occupied Both the lines...

Page 7: ...rst to penultimate smoke vent button each Malfunc tion 1 shunt connection by customer Line plug in card LE 513 continuation Parallel connection of RT 45 on LE 513 Terminal resistor for line monitoring...

Page 8: ...During a period of 30 minutes the smoke vent is triggered at intervals of 2 minutes in accordance with VdS 2581 The group plug in card can be triggered in OPEN direction viaAz signals The group plug i...

Page 9: ...llel 3 wires for each drive line simple cable length m x total current total consumption 1 2 3 4 5 6 7 8 9 10 A 3x 1 5 mm 120 60 40 30 24 20 17 15 13 12 m 3x 2 5 mm 200 100 65 50 40 33 28 25 22 20 m 5...

Page 10: ...s overridden in the case of an alarm from the Smoke and heat vent system The function Master CLOSE e g in the case of rain or a timer has a higher priority than the servo function and can be activated...

Page 11: ...g Mot a Mot b drive with SGI or ZA SG SG I black black orange 2x47kW branch box by customer terminal module EM 47 K LT MOT Mot a Mot b HS SG I SG I SGI 0 10 V 0 10 V SG 0 10 V 0 20 mA 4 20 mA BMS Mot...

Page 12: ...1 ZMP2 1 2 3 4 5 6 7 8 9 10 11 WE 516 rain wind wind 1 2 4 3 5 7 6 8 9 R W WRG 82 S 1 1 S 1 2 P3 P4 rain wind N AZ ZZ1 T ITR 79 1 6 2 7 4 3 5 230VAC 5 1 3 RTR 230 open close potential free wind rain i...

Page 13: ...w lock plug in card AE 525 A Function of DIP switches S1 1 on ON failure alarm S1 2 no function DIP switch factory setting DIP switch factory setting Function of DIP switches S1 1 on ON failure alarm...

Page 14: ...1 Bridge diagnostic pin against middle pin on line plug in card Check fuse connections cables t clamps smoke detectors and external control 2 Bridge diagnostic pin against middle pin on line plug in c...

Page 15: ...rol panel with reset button 2 Press concealed button in smoke vent button smoke vent closes 3 Red display LED in button and on line plug in unit goes out 1 Trigger external control if available 2 Smok...

Page 16: ...org Sasse Str 28 32 22949Ammersbek Tel 40 605 65 Fax 40 605 65 254 Germany 49 239 49 E Mail info dh partner com www dh partner com 2010 D H Mechatronic AG Ammersbek Technische nderungen vorbehalten Ri...