- weather plug-in card for

- wind-/ rain transmitter
- central vent button
- temperature control

- weather automatic On/ Off
- operational control central

Open/ Close

- wind force sensitivity adjustable
- signal retention time adjustable
- wind/ rain indication Closed

- Functions:

You can select an infinitely variable wind-force setting between 2 and 8 on
the Beaufort scale using the regulator on the plug-in unit.

As soon as the

wind force reaches the set value (time lag of a few seconds), the signal is
displayed on the plug-in card and, if available, on the control panel.
If the automatic weather control is ON, the system closes automatically. This
is given priority, even over an attempted opening by temperature control.
The wind signal remains active for an adjustable length of time to prevent
continuous actuator operation during gusty wind conditions. The regulator
on the plug-in unit

can be used to select the infinitely adjustable signal

storage time between 1 and 15 minutes.

Encoding WE 516

Weather plug-in card WE 516

Connection WE 516

LT 43-W

close

–N

open

P

P

S

ZZ2

–N

ZMP1

ZMP2

1

2

3

4

5

6

7

8

9

10

11

WE 516

rain

wind

wind

+

1

2

4

3

5

7

6

8

9

R

W

WRG 82

S 1/1

S 1/2

P3

P4

rain

+

wind

–N

AZ

ZZ1

–T

ITR 79

1

6

2

7

4

3

5

230VAC

5

1

3

RTR 230 *

open

close

-

potential free
wind/rain indication to
further control panels
max. 60V / 1A

Function WE 516

Automatic rain control:

Automatic temperature control:

Manual Control:

If the automatic weather control is on, the system will close automatically when it starts to rain. A signal, if available, will be indicated on module/ plug-in unit
and on the control panel.
To test, place a moist finger on the surface. Clean rain detector electrodes and insulator with mild soap water in the case of dirt accumulation and rinse off
thoroughly.

Ventilation control is carried out by a room temperature controller, if available, and if the Automatic temperature control is switched on and if no wind / or rain
signal is indicated.
If a wind / or rain signal is present, this has priority and it will close the system.

The system fully opens or closes fully by pressing the

or

button once briefly .

Pressing both buttons at the same time or pressing the “Stop” button on the operator panel stops the system at any intermediate position.
Manual control is only enabled if no wind, rain or temperature signal is being processed or if the automatic control has been deactivated.

Summary of Contents for RZN 43-E Series

Page 1: ...nstallation commissioning repair and service The highest national and international quality standards are therefore reliably fulfilled The comprehensive network of D H service and sales partners is at...

Page 2: ...d by D H for carrying out this maintenance competently and will be automatically provided with the latest maintenance instructions Following tests must be carried out during maintenance External exami...

Page 3: ...heat ventilation system under alarm conditions will occur if the inner temperature exceeds 72 C caused by the radiant heat from a fire in the immediate vicinity of the installation location VE 530 Se...

Page 4: ...er power lines In case of a cable with green yellow this must Cable and terminal boxes have to be labeled ground wire not be used Slot E1 E2 AM 44 Z Alarm cutoff module TR 42 Cutoff relay module WFR 4...

Page 5: ...function can be deactivated via the servicetool Attention Reset of the service timer can be carried out by a specialist company only who has been authorized by the appliance manufacturer close red gre...

Page 6: ...switched OFF ON for Smoke Detector Reset at the control panel This line is released by a line connected in series Every previous plug in slot after the releasing line must be occupied Both the lines...

Page 7: ...rst to penultimate smoke vent button each Malfunc tion 1 shunt connection by customer Line plug in card LE 513 continuation Parallel connection of RT 45 on LE 513 Terminal resistor for line monitoring...

Page 8: ...During a period of 30 minutes the smoke vent is triggered at intervals of 2 minutes in accordance with VdS 2581 The group plug in card can be triggered in OPEN direction viaAz signals The group plug i...

Page 9: ...llel 3 wires for each drive line simple cable length m x total current total consumption 1 2 3 4 5 6 7 8 9 10 A 3x 1 5 mm 120 60 40 30 24 20 17 15 13 12 m 3x 2 5 mm 200 100 65 50 40 33 28 25 22 20 m 5...

Page 10: ...s overridden in the case of an alarm from the Smoke and heat vent system The function Master CLOSE e g in the case of rain or a timer has a higher priority than the servo function and can be activated...

Page 11: ...g Mot a Mot b drive with SGI or ZA SG SG I black black orange 2x47kW branch box by customer terminal module EM 47 K LT MOT Mot a Mot b HS SG I SG I SGI 0 10 V 0 10 V SG 0 10 V 0 20 mA 4 20 mA BMS Mot...

Page 12: ...1 ZMP2 1 2 3 4 5 6 7 8 9 10 11 WE 516 rain wind wind 1 2 4 3 5 7 6 8 9 R W WRG 82 S 1 1 S 1 2 P3 P4 rain wind N AZ ZZ1 T ITR 79 1 6 2 7 4 3 5 230VAC 5 1 3 RTR 230 open close potential free wind rain i...

Page 13: ...w lock plug in card AE 525 A Function of DIP switches S1 1 on ON failure alarm S1 2 no function DIP switch factory setting DIP switch factory setting Function of DIP switches S1 1 on ON failure alarm...

Page 14: ...1 Bridge diagnostic pin against middle pin on line plug in card Check fuse connections cables t clamps smoke detectors and external control 2 Bridge diagnostic pin against middle pin on line plug in c...

Page 15: ...rol panel with reset button 2 Press concealed button in smoke vent button smoke vent closes 3 Red display LED in button and on line plug in unit goes out 1 Trigger external control if available 2 Smok...

Page 16: ...org Sasse Str 28 32 22949Ammersbek Tel 40 605 65 Fax 40 605 65 254 Germany 49 239 49 E Mail info dh partner com www dh partner com 2010 D H Mechatronic AG Ammersbek Technische nderungen vorbehalten Ri...

Reviews: