Figure 3.10 - Renew Period Page
The Renew Period gives the time interval for CWM to refresh the dynamic IP
address for the connection to the remote web page.
In order to use Cytech’s IP redirection system, check the box in the above
screen.
Cytech’s dynamic IP redirection service is hosted on the company’s web server.
The user registers with a username and password on the setup screen. CWM
will send its IP address periodically to the allocated space on the website. To
access the CWM from any browser on the internet point the browser to the
URL:
https://www.cytech-technology.com/dynip/username.php
where “username” is the user name which is entered in the Dynamic IP setup
page. The browser will be redirected to the actual IP address of the CWM. Note
that the Cytech web site does not host the users CWM pages or gather any
information about the CWM other than its IP address. However it must be noted
that anyone who enters the same URL will be redirected to the CWM at the IP
address. Anyone who has inadvertently or deliberately reached the CWM IP
address must know the User code of the Comfort system in order to sign in. If
there are 6 unsuccessful attempts to sign in on the CWM web page (also applies
to keypad or telephone), the Sign In Tamper Alarm will be activated which will
lock out further attempts.