35
CABLE SETUP
2ND LEVEL
3RD LEVEL
Type
COPPER
Optical
Delay
ON
Off
Level
NORMAL
Strict
Length
2M
3m
4m
5m
Time
2 MINUTE
5 minute
10 minute
15 minute
30 minute
1 hour
Infinite
1) Type:
Select the type of cable being tested, standard copper cable or
optical (AOC) cable.
Note: The option is only available with hardware revision R3 or later.
2) Delay:
Enable or disable adding a slight delay to the CEC & ARC signal
feature tests to compensate for cable design differences. If an AOC cable
fails the CEC & ARC tests with this on, retest with it turned off.
Note: This is the only configuration option when Type is set to “Optical”.
3) Level:
Select the strictness level of the error testing performed. Selecting
normal is recommended for standard cables.
4) Length:
Select the length of the copper cable being tested.
5) Time:
Select the length of time to perform error testing on copper cable.
Summary of Contents for CPHD-V4L
Page 2: ...registered trademarks of HDMI licensing Administrator Inc...
Page 74: ......
Page 75: ......