Cygnus DIVE Operating Manual
M3-DIVE-M-ENG_Iss9.docx
Page 92 of 117
Each group of measurements in the DIVE gauge will be transferred
into a new Survey Group in CygLink.
If you repeat the transfer a second time, the measurements will be
appended to the Survey again in new Survey Groups.
Logging Measurements Directly in CygLink
You can use CygLink to log the displayed topside thickness
measurements into a Survey so they can be presented in the
Survey report.
Clicking the
Log
button next to the thickness measurement will
create a new record and add a measurement into the group.
Reference and Minimum Thickness Criteria
You can set a Reference Thickness and Minimum Thickness for
each survey Group right clicking on the records number and select
properties. This will be applied to all measurements in the Group.
The Reference Thickness is the thickness of metal when new.
The Minimum Thickness is the minimum thickness
–
any
measurement below this will be highlighted Red on the screen and
in the survey report.
Pre-Set Measurement Comments List
You can add up to 8 short text comments that can then be used to
append to a thickness measurement. To setup your comments
click
File
->
Measurement Comments
.