Maintenance Menu
Section 4.3
This is a feature using the serial port to set up certain
parameters and to interrogate the settings within the printers’
memory. Using a non-standard data cable (example in section 3)
connect the printer to a PC. A 24 volt Power supply is also needed,
connect this to the power connection described in section 3. Use
HyperTerminal
or another similar “dumb” terminal program on the
PC to communicate with the printer.
To enter the internal maintenance program type “Ctrl” + “s”. To
exit this mode type “Esc”.
The settings are as follows:
1. Set time & date – enter time in 24 hour format, that is, if
the time is 2:30pm – enter 14:30. If the date is August 8,
2008, it would entered as 08-08-08. Always include leading
zero’s in both time and date. The “:” in time, and the “-“’
are automatically displayed, so there is no need to enter
them.
2. Display time will show the existing internal settings.
3. Display reprint information – displays the “Start” and “Stop”
sequences, as well as whether a valid message appears in
memory.
4. Display PC board serial number – allows view of factory set
pcb number (usually matches printer serial number).
5. Display manufacturing date – displays factory set date of
test, usually matches ship date.
6. Display status – allows current status of the printer errors
for debug purposes.
7. Display IP configuration - gateway, IP address, subnet mask,
and mac address.
8. Set IP address - enter new IP address - 192.168.1.xx
9. Set subnet mask - 255.255.255.xx
Summary of Contents for PX922E