CyberPower CPS1000AVR User Manual Download Page 8

 

 

8

As the battery discharges, the unit will beep more rapidly, indicating that the battery is nearing discharge.    Once the test is 
complete, plug the UPS back in to the AC outlet and start your computer. Please allow 4 hours for the UPS to recharge 
before attempting another self-test. 
 

REPLACING THE BATTERY 

 

CAUTION!

   

Read and follow the 

IMPORTANT SAFETY INSTRUCTIONS

 before servicing the battery.   

Service the 

battery under the supervision of personnel knowledgeable of batteries and their precautions. 
 

CAUTION! 

  Use only the specified type of battery.   

See your dealer for replacement batteries. 

 

CAUTION!

   

The battery may present risk of electrical shock.    Do not dispose of battery in a fire, as it may 

explode.    Follow all local ordinances regarding proper disposal of batteries. 

 

CAUTION!

    Do not open or mutilate the batteries.    Released electrolyte is harmful to skin and eyes and may be toxic. 

 

CAUTION! 

 

A battery can present a high risk of short circuit current and electrical shock.     

 
Take the following precautions before replacing the battery: 

1. 

Remove all watches, rings or other metal objects. 

2. 

Only use tools with insulated handles. 

3. 

Do not lay tools or metal parts on top of battery or any terminals. 

4. 

Wear rubber gloves and boots. 

5. 

Determine if the battery is inadvertently grounded.    If inadvertently grounded, remove source of ground.   

CONTACT WITH GROUNDED BATTERY CAN RESULT IN ELECTRICAL SHOCK!   

The likelihood of such 

shock will be reduced if such grounds are removed during installation and maintenance (applicable to a UPS 
and a remote battery supply not having a grounded circuit). 

 

TO REPLACE THE BATTERY 

1. 

Turn off and unplug all connected equipment. 

2. 

Turn the UPS off and unplug it from the AC power source. 

3. 

Turn the UPS upside down. 

4. 

Remove the 6 retaining screws. 

5. 

Turn the UPS right side up and remove the outlet cover. 

6. 

Remove the battery from the compartment. 

7. 

Disconnect the battery wires from the battery. 

8. 

Install the replacement battery by connecting the 

red wire to the positive (+) terminal    of the battery

 and 

connecting the 

black wire to the negative (-) terminal of the    battery.

 

9. 

Slide the battery back into the compartment. 

10. 

Replace the outlet cover and the 6 retaining screws. 

11. 

Recharge the unit for 4 – 8 hours to ensure the UPS performs expected runtime. 

 

REMINDER:  

Batteries are consider 

HAZARDOUS WASTE

 and must be disposed properly.    Contact your local 

government for more information about proper disposal and recycling of batteries. 

Summary of Contents for CPS1000AVR

Page 1: ...unplug all electrical equipment from the outlet and have an electrician check the outlet to insure proper wiring 8 AVR Indicator This LED indicates that the UPS is operating in automatic voltage regul...

Page 2: ...jack on the UPS with the CPU icon to the modem port of the computer The out jack with the telephone icon can be used to protect a telephone or fax machine line 5 Plug the UPS into a properly grounded...

Page 3: ...and unplug it 9 Connect the serial interface to the UPS and an open serial port on the computer Note You must one of the cables that was supplied with the unit 10 Plug the UPS into an AC outlet turn t...

Page 4: ...PANEL PLUS SOFTWARE USER MANUAL PowerPanel Plus version 1 13 or greater is designed for use with Windows 95 Windows 98 Windows Me Windows NT and Windows 2000 The latest version can be downloaded from...

Page 5: ...ad on the system This indicator can appear in red yellow or green depending upon the number of minutes available 7 Scheduled Off PowerPanel Plus can be set to automatically shutdown the computer syste...

Page 6: ...f AC power To maximize battery life it is recommended to keep this disabled 6 Default Restores the settings to the factory defaults 7 Cancel Exits the window without saving changes 8 OK Exits the wind...

Page 7: ...hat the UPS has been charged for at least 4 hours before performing this test If you are using PowerPanel Plus 1 With your UPS and computer on open an application such as notepad 2 Enter some data int...

Page 8: ...Do not lay tools or metal parts on top of battery or any terminals 4 Wear rubber gloves and boots 5 Determine if the battery is inadvertently grounded If inadvertently grounded remove source of ground...

Page 9: ...sintheBattery power SuppliedOutlets TurntheUPSoffandunplug atleastonepieceofequipmentfromtheUPS Wait5seconds resetthecircuitbreakerand turntheUPSon On On Off On Fla sh Off Off On Set None WeakBattery...

Page 10: ...an additional serial port Move the cable to this port The unit is not providing battery power Shutdown your computer and turn the UPS off Wait 10 seconds and turn the UPS back on This should reset the...

Page 11: ...t and therefore entitled coverage under the Limited Warranty and the Power Control Guarantee Registration is not required for Limited Warranty coverage but note if you do not complete a registration c...

Page 12: ...ample a sales receipt that establishes you as the Initial Customer the original consumer purchaser of the Product within ten 10 days of the event for which you want to make a claim for warranty servic...

Page 13: ...ded and code compliant 120 volt power lines in the United States and Canada transients surges or spikes on standard telephone land lines PBX telephone equipment lines or Base 10 100T Ethernet lines wh...

Reviews: