CyberPower CPS1000AVR User Manual Download Page 2

 

 

2

1. 

Your new UPS may be used immediately upon receipt.    However, 

recharging the battery for at least four 

hours

 is recommended to insure that the battery’s maximum charge capacity is achieved.    Charge loss may 

occur during shipping and storage.    To recharge the battery, simply leave the unit plugged into an AC outlet.   
The unit will charge in both the on, as well as the off, position. 

 
2. 

If you wish to use the software, connect either the enclosed serial 

interface or USB adapter cable to the serial port on the UPS and an 
open serial or USB port on the computer.    If you are not going to 
use the software, you do not need to connect a cable. 

 

3. 

With the UPS unit off and unplugged, connect your computer, 
monitor, and any externally powered data storage device (Zip drive, Jazz 
drive, Tape drive, etc…) into the battery power supplied outlets.    Plug 
your peripheral equipment (printer, scanner, speakers) into the    full-time 
surge protection outlets.   

DO NOT plug a laser printer, copier, space 

heater, vacuum or other large electrical device into the UPS.    The 
power demands of these devices will overload and possibly damage 
the unit. 

 

4. 

To protect a fax, telephone or modem line, connect a telephone 

cable from the wall jack outlet to the in jack of the UPS.    Connect a 
telephone cable the out-jack on the UPS with the CPU icon to the 
modem port of the computer.    The out-jack with the telephone icon 
can be used to protect a telephone or fax machine line.

 

 

5. 

Plug the UPS into a properly grounded wall outlet.    Make sure the 
wall outlet is protected by a fuse or circuit breaker and does not 
service equipment with large electrical demands (e.g. refrigerator, copier, etc…).  Avoid using extension 
cords.    If used, the extension cord must be rated for 15 amps. 

 
6. 

Depress the power switch to turn the unit on.    The power on indicator light will illuminate. 

 
7. 

If an overload is detected, an audible alarm will sound and the unit will emit one long beep.    To correct this, 
turn the UPS off and unplug at least one piece of equipment from the battery power supplied outlets.    Wait 10 
seconds.    Make sure the circuit breaker is depressed and then turn the UPS on. 

 

8. 

Your UPS is equipped with an auto-charge feature.    When the UPS is plugged into an AC outlet, the battery 
will automatically recharge. 

 
9. 

To maintain optimal battery charge, leave the UPS plugged into an AC outlet at all times. 

 
10. 

To store your UPS for an extended period, cover it and store with the battery fully charged.    Recharge the 
battery every three months to insure battery life. 

 

POWERPANEL PLUS™ SOFTWARE INSTALLATION GUIDE 

(Note:  

Use of the software is optional.

    The UPS will provide surge suppression and battery backup without the 

software.    You must use the software if you wish to have the automatic shutdown feature). 

 

 

Summary of Contents for CPS1000AVR

Page 1: ...unplug all electrical equipment from the outlet and have an electrician check the outlet to insure proper wiring 8 AVR Indicator This LED indicates that the UPS is operating in automatic voltage regul...

Page 2: ...jack on the UPS with the CPU icon to the modem port of the computer The out jack with the telephone icon can be used to protect a telephone or fax machine line 5 Plug the UPS into a properly grounded...

Page 3: ...and unplug it 9 Connect the serial interface to the UPS and an open serial port on the computer Note You must one of the cables that was supplied with the unit 10 Plug the UPS into an AC outlet turn t...

Page 4: ...PANEL PLUS SOFTWARE USER MANUAL PowerPanel Plus version 1 13 or greater is designed for use with Windows 95 Windows 98 Windows Me Windows NT and Windows 2000 The latest version can be downloaded from...

Page 5: ...ad on the system This indicator can appear in red yellow or green depending upon the number of minutes available 7 Scheduled Off PowerPanel Plus can be set to automatically shutdown the computer syste...

Page 6: ...f AC power To maximize battery life it is recommended to keep this disabled 6 Default Restores the settings to the factory defaults 7 Cancel Exits the window without saving changes 8 OK Exits the wind...

Page 7: ...hat the UPS has been charged for at least 4 hours before performing this test If you are using PowerPanel Plus 1 With your UPS and computer on open an application such as notepad 2 Enter some data int...

Page 8: ...Do not lay tools or metal parts on top of battery or any terminals 4 Wear rubber gloves and boots 5 Determine if the battery is inadvertently grounded If inadvertently grounded remove source of ground...

Page 9: ...sintheBattery power SuppliedOutlets TurntheUPSoffandunplug atleastonepieceofequipmentfromtheUPS Wait5seconds resetthecircuitbreakerand turntheUPSon On On Off On Fla sh Off Off On Set None WeakBattery...

Page 10: ...an additional serial port Move the cable to this port The unit is not providing battery power Shutdown your computer and turn the UPS off Wait 10 seconds and turn the UPS back on This should reset the...

Page 11: ...t and therefore entitled coverage under the Limited Warranty and the Power Control Guarantee Registration is not required for Limited Warranty coverage but note if you do not complete a registration c...

Page 12: ...ample a sales receipt that establishes you as the Initial Customer the original consumer purchaser of the Product within ten 10 days of the event for which you want to make a claim for warranty servic...

Page 13: ...ded and code compliant 120 volt power lines in the United States and Canada transients surges or spikes on standard telephone land lines PBX telephone equipment lines or Base 10 100T Ethernet lines wh...