CyberPower CPS1000AVR User Manual Download Page 3

CPS1000AVR  

Guaranteed Uninterruptible Power System

 

 

3

 
FOR WINDOWS 95/98/Me 

1. 

Turn the UPS off and unplug it. 

2. 

Connect the serial interface or USB adapter cable to the UPS and an open serial or USB port on the   
computer.    (Note:    You must one of the cables that was supplied with the unit). 

3. 

Plug the UPS into an AC outlet, turn the UPS on and then start your computer. 

4. Windows 

will 

find 

New Hardware

5. 

Insert the software disk into the floppy drive. 

6. 

Follow the on-screen instructions. 

7. 

Once the software is installed, remove the floppy disk and restart your computer. 

 

When your computer restarts, the PowerPanel Plus™ software will appear on your screen for a few seconds, and 
then minimize.    It will appear as a blue and white battery icon located in the system tray, near the clock. 

 

 
 
 
 
 
FOR WINDOWS NT 
 

1. Click 

on 

Start

, point to 

Settings

, and then click 

Control Panel

2. 

Double-click on the 

UPS Icon

3. 

Remove the check mark from the box labeled 

UPS is installed on

4. Click 

OK

5. 

Acknowledge the message that the UPS is in an unknown state. 

6. Exit 

to 

the 

desktop. 

7. Shutdown 

your 

computer. 

8. 

Turn the UPS off and unplug it. 

9. 

Connect the serial interface to the UPS and an open serial port on the computer.    (Note: You must one of   
the cables that was supplied with the unit). 

10. 

Plug the UPS into an AC outlet, turn the UPS on and then start your computer. 

11. Click 

on 

Start

, point to 

Settings

, and then click 

Control Panel

12. Double-click 

on 

Add/Remove Programs

13. 

Insert the software disk into the floppy drive. 

14. Click 

Install

15. 

Follow the on-screen instructions. 

16. 

Once the software is installed, remove the floppy disk and restart your computer. 

 

When your computer restarts, the PowerPanel Plus™ software will appear on your screen for a few seconds, and 
then minimize.    It will appear as a blue and white battery icon located in the system tray, near the clock. 

 
 
 
 
 
 
 
FOR WINDOWS 2000 

 

1. 

Click on Start, point to Settings, and then click Control Panel.   

2. 

Double-click on Power Options. 

3. 

On the UPS Tab, click Select. 

4. 

In the UPS Selection Dialog Box, under Manufacturers, click None. 

5. Exit 

to 

the 

desktop. 

6. 

Shutdown the computer. 

7. 

Turn the UPS off and unplug it. 

8. 

Connect the serial interface or USB adapter cable to the UPS and an open serial or USB port on the computer.   
(Note:    You must use one of the cables that was supplied with the unit). 

9. 

Plug the UPS into an AC outlet, turn the UPS on and then start your computer. 

Summary of Contents for CPS1000AVR

Page 1: ...unplug all electrical equipment from the outlet and have an electrician check the outlet to insure proper wiring 8 AVR Indicator This LED indicates that the UPS is operating in automatic voltage regul...

Page 2: ...jack on the UPS with the CPU icon to the modem port of the computer The out jack with the telephone icon can be used to protect a telephone or fax machine line 5 Plug the UPS into a properly grounded...

Page 3: ...and unplug it 9 Connect the serial interface to the UPS and an open serial port on the computer Note You must one of the cables that was supplied with the unit 10 Plug the UPS into an AC outlet turn t...

Page 4: ...PANEL PLUS SOFTWARE USER MANUAL PowerPanel Plus version 1 13 or greater is designed for use with Windows 95 Windows 98 Windows Me Windows NT and Windows 2000 The latest version can be downloaded from...

Page 5: ...ad on the system This indicator can appear in red yellow or green depending upon the number of minutes available 7 Scheduled Off PowerPanel Plus can be set to automatically shutdown the computer syste...

Page 6: ...f AC power To maximize battery life it is recommended to keep this disabled 6 Default Restores the settings to the factory defaults 7 Cancel Exits the window without saving changes 8 OK Exits the wind...

Page 7: ...hat the UPS has been charged for at least 4 hours before performing this test If you are using PowerPanel Plus 1 With your UPS and computer on open an application such as notepad 2 Enter some data int...

Page 8: ...Do not lay tools or metal parts on top of battery or any terminals 4 Wear rubber gloves and boots 5 Determine if the battery is inadvertently grounded If inadvertently grounded remove source of ground...

Page 9: ...sintheBattery power SuppliedOutlets TurntheUPSoffandunplug atleastonepieceofequipmentfromtheUPS Wait5seconds resetthecircuitbreakerand turntheUPSon On On Off On Fla sh Off Off On Set None WeakBattery...

Page 10: ...an additional serial port Move the cable to this port The unit is not providing battery power Shutdown your computer and turn the UPS off Wait 10 seconds and turn the UPS back on This should reset the...

Page 11: ...t and therefore entitled coverage under the Limited Warranty and the Power Control Guarantee Registration is not required for Limited Warranty coverage but note if you do not complete a registration c...

Page 12: ...ample a sales receipt that establishes you as the Initial Customer the original consumer purchaser of the Product within ten 10 days of the event for which you want to make a claim for warranty servic...

Page 13: ...ded and code compliant 120 volt power lines in the United States and Canada transients surges or spikes on standard telephone land lines PBX telephone equipment lines or Base 10 100T Ethernet lines wh...

Reviews: