Operations Guide
931281I
CyberData Corporation
2.3.10 Configure the Sensor Page Parameters
The door sensor (pins 1 and 2) on the terminal block can be used to monitor a door's open or closed
state. There is an option on the
to trigger on an open or short condition on these pins.
The door sensor alarm will be activated when the
parameter has
been met.
Each sensor can trigger up to five different actions:
•
Flash the LED until the sensor is deactivated (roughly 10 times/second)
•
Activate the relay until the sensor is deactivated
•
Loop an audio file out of the speaker until the sensor is deactivated
•
Call an extension and establish two way audio
•
Call an extension and play a pre-recorded audio file
Note
Calling a preset extension can be set up as a point-to-point call, but currently can't send
delayed DTMF tones.
1. Click
Sensor
menu button to open the
(
Summary of Contents for InformaCast Enabled 011406
Page 80: ...Operations Guide 931281I CyberData Corporation Figure 2 41 SSL Configuration Page ...
Page 81: ...Operations Guide 931281I CyberData Corporation Figure 2 42 SSL Configuration Page ...
Page 90: ...Operations Guide 931281I CyberData Corporation Figure 2 47 Audiofiles Page ...
Page 91: ...Operations Guide 931281I CyberData Corporation Figure 2 48 Audiofiles Page ...