Fitting the Metal Fascia
•
See information above for details of the Air Intake requirements.
•
WARNING:
the Enclosure on the Metal Fascia must be flush with the wall before
attempting to fit the fascia.
•
Put the fascia against the wall so that the lower edge is level with the shelf.
•
Draw around the fascia.
•
Remove fascia and turn over.
•
Measure positions of screw key holes and mark this onto the wall.
•
Drill and Plug holes. Fit Suitable Screws to a depth to ensure the fascia locks
against the wall when fitted.
•
With the help of an assistant, lift the Fascia towards fire.
•
Unclip the remote magic eye and plug this into the remote box as shown on the
wiring diagram.
•
Lift fascia onto the wall until key holes line up then pus fascia down to lock in
place.
•
WARNING:
The fascia must sit off the wall 40mm. It must never be installed
“flush” into the wall or plaster. The fascia has an air vent which runs along the
bottom. This plus the specified air intake area ensure the burner and flame perform
as required. Failure to do this will result in serious burner damage and this is NOT
covered by the warranty.