Page 13 of 46
Installation Instructions
General
This Fire Ribbon unit is intended for decorative purposes. The installation
must be in accordance with National Regulations and must be carried out
by a qualified installer.
Clearances between the fire and all combustible materials must conform to
National Regulations.
This fire must be installed and used in accordance with these instructions.
Prior to installation, ensure that the local distribution conditions
(identification of the type of gas and pressure and the adjustment of the
appliance) are compatible.
The builders opening or fireplace opening must be constructed of a non-
combustible material.
For some countries a purpose provided air supply must be fitted in
accordance with National Regulations (e.g. United Kingdom - minimum 100
cm2)
When installed, this unit should be located to the rear of the fire opening.
For some countries a non-combustible hearth must be fitted in front of the
fire in accordance with National Regulations (e.g. United Kingdom).
Any flue damper plate or flue restrictor must be removed or fixed
permanently in a fully open position, or shall only be fitted in accordance
with National Regulations.
The chimney must be swept before the appliance is installed.
NOTE:
If the chimney is not swept, there is a possibility that loose debris
will fall onto the appliance which may result in damage and unnecessary
service costs. A simple smoke test will determine if the flue is working
correctly.
Before the fire is installed a flue test in accordance with National
Regulations should be carried out. The unit must not be installed unless
the chimney / flue length is at least the length and size indicated in
the ‘Technical Data’ section.
Under no circumstances should this unit be installed and operated within
any premises without an adequate flue or chimney system.
Summary of Contents for Double Sided Fire Ribbon
Page 18: ...Page 18 of 46 Fitting the Enclosure...
Page 19: ...Page 19 of 46...
Page 20: ...Page 20 of 46...
Page 21: ...Page 21 of 46...
Page 22: ...Page 22 of 46...
Page 28: ...Page 28 of 46 Guidance on Ventilation and Sealing...
Page 32: ...Page 32 of 46 Remote Control Components Black Box Remote Valve NG Version LPG Version...
Page 34: ...Page 34 of 46 NG Remote Wiring Diagram...
Page 35: ...Page 35 of 46 LPG Remote Wiring Diagram...
Page 39: ...Page 39 of 46...