Page 12 of 46
Burner Connections
This fire is supplied with an enclosure and integral burner.
IMPORTANT:
The appliance is supplied with a fully tested and working gas
burner. There is no need to dismantle the burner. This could result in
damage to the fire which is not covered by the warranty. No connections
should be removed or broken.
Removal of any connections will result
in the warranty being invalidated.
The Fire requires 3 connections:
1.
GAS SUPPLY
The fire has an 8mm inlet via an isolation valve. The fire also includes a
pressure test point elbow to test inlet pressure. The gas pipe work should
be routed into the enclosure via the available access holes. If the gas pipe
work is over 1.5mtrs in length it is recommended that the pipe work is
increased in diameter from this point to 15mm and possibly 22mm
depending on the length to the meter. This will ensure a stable gas supply.
2.
HARD WIRE REMOTE
The hard wire remote has a switch connected. This cable should be routed
from the appliance to a position which is suitable for the user. If it is
required to remove the switch plate in order to install into the wall great
care must be taken when removing the switch. The switch has a “top”
marked on it. The cables must be fitted back in the same sequence
otherwise remote damage will occur.
3.
MAINS VOLTAGE
This is via a black cable. This must be fitted to a 3A 240V fused spur supply
which is within access of the user should the fuse need changing. This is
the power source for the remote control system.
Great care must be taken when handling the burner and hard wire system.
Burner Removal
Removal of the burner will invalidate the warranty. If the burner
needs to be removed for repair follow the below steps:
•
Remove the front shelf.
•
Remove the 2 screws on each side which hold the shelf mounting
brackets to the enclosure.
•
Disconnect the gas and electricity supply.
•
The burner carriage is screwed to the bottom of the enclosure by 2
screws. Once removed the full burner assembly will lift out.
•
Refit is the same procedure in reverse.
•
The fire should be commissioned once refitted.
Summary of Contents for Double Sided Fire Ribbon
Page 18: ...Page 18 of 46 Fitting the Enclosure...
Page 19: ...Page 19 of 46...
Page 20: ...Page 20 of 46...
Page 21: ...Page 21 of 46...
Page 22: ...Page 22 of 46...
Page 28: ...Page 28 of 46 Guidance on Ventilation and Sealing...
Page 32: ...Page 32 of 46 Remote Control Components Black Box Remote Valve NG Version LPG Version...
Page 34: ...Page 34 of 46 NG Remote Wiring Diagram...
Page 35: ...Page 35 of 46 LPG Remote Wiring Diagram...
Page 39: ...Page 39 of 46...