Adjust and Function Specification
§
Cd23 Braking mode (Settable range 0-3)
This function must accommodate Cd24, Cd25, and Cd26.
Cd23=0 No DC braking
Cd23=1 Stop mode
Cd23=2 Start mode
Cd23=3 Stop and start mode
§
Cd24 DC braking frequency (Settable range 1-60)
This function must accommodate Cd23, Cd25, and Cd26.
Set frequency of DC brake starts at the time of inverter deceleration stops,
the DC brake is active when operates below the starting frequency.
§
Cd25 DC braking voltage (Settable range 1-15)
This function must accommodate Cd23, CD24, and Cd26.
DC braking torque setting
When DC brake is active, monitor displays “dCbr”
Cd25=1-15, the higher value the higher output brake torque
Note:
When DC brake voltage is high, be aware of over current.
§
Cd26 DC braking time (Settable range 1-60)
Adjust DC braking time