Adjust and Function Specification
§
Cd01 Setting procedure of frequency (Selective range 0-7)
The function cannot be modified during revolution.
Setting procedure of frequency is to select either panel key or external analog signal.
Cd01=0
Set frequency on operation panel, as the above items A-C.
Cd01=1
Set frequency by terminal In2 DC 0-10V/5K
Ω
VR
Cd01=2
Set frequency by terminal In1 DC 4-20mA
Cd01=3
Set frequency by terminal In2+IN3 DC 0-10V/5K
Ω
VR
Cd01=4
Setting from terminal In2, input DC0
〜
10V/VR 5K
Ω
hysteresis
Cd01=5
Setting from terminal In1, input DC4
〜
20mA hysteresis
Cd01=6
Setting from terminal In2+IN3, input DC0
〜
10V/VR 5K
Ω
hysteresis
Cd01=7
Set frequency by Multi-step function mode
§
Cd02 Select Main monitor display (Selective range 0-15)
The monitor is consisted of four 7-segment LEDs, displays frequency, current and
various data by digital number and character.
Cd02=0
Display the frequency, LED HZ active
Cd02=1
Display the current, LED I active
Cd02=2
Display Ultimate speed, Hz and I LED de-active.
Cd02=3
Display DC voltage of DC BUS, showing d in front of value
Cd02=4
Display rms value of U.V.W. AC output
,
LED HZ, I active
Cd02=5
Display external control terminal status, showing E in front of value
Cd02=6
Display temperature rising of PIM module, showing b in front of value
Cd02=7
Display speed feedback. Check if MCK circuit working properly, then
the restart and free run start function (Cd28) will working normally.
Cd02=8
Display average speed of multi-step function (rpm)
Cd02=9
Display current step of multi-step function (step)
Cd02=10
Display current time of multi-step function (minutes)
Cd02=11
Display Yards counter value
Cd02=12
Display power factor (cos
Θ
)
Cd02=13
Display transient power (Kw)
Cd02=14
Display Kw-h
Cd02=15
Display Mw-h
§
Cd03 Torque mode (Selective range 0,1)
The function cannot be modified during revolution.