27
Adjust and Function Specification
Item of display
changing
Parameter
▲
selection
▼
Parameter
modification
Press
▲
,
▼
key at display mode, select required item.
Press
▲
,
▼
key to change
value when screen
shows Cd-
(General parameter input area) or
CE-
(Failure display and engineering mode). Press and
hold
▲
,
▼
key can progressively increase or
decrease
value.
Press
▲
,
▼
key at parameter input mode can change
parameter. Using with SET key to modify parameter.
Input a number
Input a number
0
9
•
D. Function Code
§
Cd00 Set frequency (settable range 0.5-240 HZ)
There are 5 methods to change set frequency. Items A~C are methods of panel key
operation, items D-E are methods of external terminal input.
A.
At display function, press READ and setting (Cd01=0)
B.
Use PROG key to input data (Cd01=0)
C. Use
▼、▲
key to input data (Cd01=0)
D. Use Multi-Step function to setting (Refer to function CE05 to CE55.)
E.
Set external voltage
F.
Set external current
Note:
1. Set value should be in accordance with V/F slope (Cd05) and upper limit
frequency (Cd17).
Set by function key
A. At display function, press READ and setting (Cd01=0)