![Curtiss-Wright EXLAR GTX Series Installation & Service Instructions Manual Download Page 9](http://html.mh-extra.com/html/curtiss-wright/exlar-gtx-series/exlar-gtx-series_installation-and-service-instructions-manual_2700317009.webp)
GTX Series Actuator Installation & Maintenance Instructions |
9
www.exlar.com
| 952.500.6200
3.2.4 External Limit Switches
This option allows multiple external switches (sold separately)
to be externally mounted to the actuator. These adjustable
switches provide travel indication to the controller. A bracket
with inductive proximity switches mounts to the outside low-
profile extrusion and senses a traveling magnet located inside
the anti-rotate tube.
Figure 7 –
Limit switch mounting
GTX080: 2.5 mm Hex
GTX100: 5 mm Hex
GTX080: Torque 0.6 Nm (0.5 ft-lbs)
GTX100: Torque 9.5 Nm (7 ft-lbs)
GTX080: 5 mm Hex
GTX100: 8 mm Hex
5 mm Hex
6 mm Hex
Torque 9.5 Nm (7 ft-lbs)
Torque 21.7 Nm (16 ft-lbs)
GTX080: Torque 4.6 Nm (4 ft-lbs)
GTX100: Torque 12.2 Nm (9 ft-lbs)
GTX080: 5 mm Hex
GTX100: 5 mm Hex
Washer
Washer
Magnet
GTX080: Torque 4.6 Nm (4 ft-lbs)
GTX100: Torque 4.6 Nm (4 ft-lbs)