Mar 2017
Page 51
© Penny & Giles Aerospace Ltd. No part of this work may be reproduced or distributed by any
means without prior permission in writing from the copyright owner.
DATA ACQUISITION FLIGHT RECORDER Type D51615-202-XXX or D51615-
202-XXX-090- with CCU Type D51616-XXXX and CAM Type D51623-XXXX
Installation and Operating Manual with Illustrated Parts
List
Commercial in Confidence
PIM434-I
NOTE:
All screws are to be secured with Loctite 222 adhesive
(P&G P/N 500000039) or equivalent alternative unless
otherwise specified.
WARNING:
WHEN USING LOCTITE 222 ADHESIVE, THE
FOLLOWING PRECAUTIONS MUST BE OBSERVED:
AVOID BREATHING FUMES AND USE WITH ADEQUATE
VENTILATION. DO NOT GET IN EYES. IN CASE OF
CONTACT IMMEDIATELY FLUSH EYES WITH RUNNING
WATER AND SEEK IMMEDIATE MEDICAL ATTENTION.
AVOID SKIN CONTACT. IF CONTACT OCCURS,
IMMEDIATELY WASH WITH SOAP AND LUKEWARM
WATER. NO ATTEMPT IS TO BE MADE TO REMOVE THE
ADHESIVE FROM THE SKIN WITHOUT SOAP AND
WATER. DO NOT USE A SOLVENT FOR THIS PURPOSE.
(6)
Assemble the fluorosilicone ring (100) in bottom
beacon bracket (60) only. Assemble beacon brackets
(60, 70) on the ULB (50).
(7)
Rotate the ULB (50) so that the battery replacement
date can be read easily.
(8)
Attach the beacon brackets (60 and 70) to the main
assembly with four M5 cap head socket screws (80) and
washers (90). Torque-tighten the screws until the
bracket makes contact with the DAFR case.
(9)
Torque the screws (80) to approximately 6.5-7.0 Nm.
(10)
Perform the ULB Battery Test (see para 6.4.2) and the
ULB Test (6.4.3).
(11)
Return the removed ULB (50) to the manufacturer for
safe disposal of the internal Lithium battery.
NOTE:
Return the removed ULB to the manufacturer for safe
disposal of the internal Lithium battery.
6.4.5 ULB Removal and Replacement - 90-Day Beacon
(1)
Release the two cap-head screws securing the retention
foot fittings on the front face of the MPFR to the retention
plate.
(2)
Remove the two longer cap-head screws and washers from
the top mounting bracket locations.