TROUBLE SHOOTING CONTINUED:

Replace thermostat if contacts are open when knob is fully clockwise and water temperature 

is less than 190º F. You will measure 120 volts (approximately) to ground from both thermostat 

terminals when it is ON and from only one terminal when it is OFF.

In this water boiler there are two elements in parallel. Failure of either will cause very slow heat-

ing. Perform the following tests:

a.  Clamp-on ammeter test: If both elements are good, you will measure about 21 amps at 240 

volts, 24 amps at 208 volts or 29 amps at 120 volts. If you measure only 10 to 12 amps, 

check the current to each element to identify the defective part.

b.  Ohmmeter or continuity test: Disconnect all power by unplugging unit. Disconnect one 

terminal to measure each element. They should each have continuity or measure about 20 

ohms.

2.  Defective thermostat

3.  Heating element burned  

 out.

SOLUTION

POSSIBLE CAUSE

PROBLEM: WATER DOES NOT REACH PROPER TEMPERATURE

Electric Thermostat 

Adjustment

ELECTRIC THERMOSTAT ADJUSTMENT

On electric water boilers, thermostats are set at the factory to cut off at 200ºF. We do not 

recommend changing this. If necessary, adjustment is as follows:

1.  Rotate the thermostat knob to the right to the BOIL position. Pull off the knob. 
2.  Locate the tiny adjustment screw, inside the stem (see figure 1). Using a small screw

-

driver, adjust the temperature up or down:

a.  By turning the screw ¼ turn to the left will increase the temperature about 20°F.
b.  Turning ¼ to the right will decrease the temperature by 20°F.
c.  To set the thermostat precisely at 200°F, insert a thermometer probe into the 

water jacket through the steam hole (just under the sprayhead). Turn the screw ½ 

turn to the left. 

d.  When the thermometer reaches 200°F, slowly turn the adjustment screw to the 

right until the pilot light turns off.

CLEANING

Regular cleaning and preventive maintenance is essential in keeping your water boiler looking and working like new. To clean the 

water boiler, prepare a mild solution of dish detergent and warm water. Turn the thermostat dial to OFF and allow the unit to cool.

CAUTION – Do not use cleansers, bleach liquids, powders or any other substance containing chlorine. These products 

promote corrosion and will pit the stainless steel. USE OF THESE PRODUCTS WILL VOID THE WARRANTY.

DAILY CLEANING

1.  Wipe exterior surfaces with a damp cloth, removing spills and debris.

2.  Remove the lid and clean it with a cloth soaked in a mild detergent solution.

3.  Rinse and dry the lid.
4.  Wipe off any traces of the cleaning solution with a cloth dampened with water.
5.  Dry the cabinet surfaces.
6.  Rub a stainless steel polish on the outside surfaces to protect the cabinet.

5

Summary of Contents for WB-14-12

Page 1: ...LATION This Curtis unit is pre set and ready to go from the factory System Requirements Water Supply 20 90 PSI Min Flow Rate 2 gpm Electrical Refer to Electrical Schematic Factory Settings Water Temperature 200ºF Water Volume 14 Gallons NOTE A water filtration system must be used to help maintain trouble free operation In areas with extremely hard water we highly recommend the use of a Curtis appr...

Page 2: ...CTRIC THERMOSTAT VALVE INLET BRASS 50 GPM 120V 10W FOR WB 14 12 VALVE INLET BRASS 50 GPM 220V 10W FOR WB 14 60 REPAIR KIT INLET VALVE KIT HEATING ELEMENT 3 5KW 220V W JAM NUTS SLCN WSHRS THERMOMETER DIAL RU S Parts List Setup Steps Continued 3 Connect the water line to the water inlet fitting on the rear of the unit Water volume going to the machine should be consistent Use tubing sized sufficient...

Page 3: ...Illustrated Parts List 3 1 2 3 4 5 6 7 8 9 10 11 19 19A 13 14 15 12 16 17 18 20 21 22 ...

Page 4: ...lace the water filter Turn machine off Disconnect wires from water inlet coil terminals and connect a power cord to the terminals Plug cord into a 120V outlet and verify if water flows when plugged in and stops when power is disconnected If valve fails this test replace valve When the water level gets below the probe tip water should automatically refill the unit If not pull wire off the probe ter...

Page 5: ...ion Pull off the knob 2 Locate the tiny adjustment screw inside the stem see figure 1 Using a small screw driver adjust the temperature up or down a By turning the screw turn to the left will increase the temperature about 20 F b Turning to the right will decrease the temperature by 20 F c To set the thermostat precisely at 200 F insert a thermometer probe into the water jacket through the steam h...

Page 6: ...Electrical Diagram WB 14 12 6 ...

Page 7: ...Electrical Diagram WB 14 60 7 ...

Page 8: ...per voltage Equipment must be installed at the voltage stated on the serial plate supplied with this equipment 4 Improper water supply This includes but is not limited to excessive or low water pressure and inadequate or fluctuating water flow rate 5 Adjustments and cleaning The resetting of safety thermostats and circuit breakers programming and temperature adjustments are the responsibility of t...

Reviews: