PROBLEM: WATER OVERFLOWING.

POSSIBLE CAUSE

SOLUTION

Turn power off and observe water level. If water continues to flow into the heating tank, clean or 

replace leaky valve.

Disconnect the wire from probe terminal and touch the body of the heating tank with the terminal at 

the end of this wire. If the flow of water stops, there is an issue with the probe. Clean the probe and 

reconnect the wire. If water continues to flow, replace the liquid level probe.

Liquid level control board must be securely grounded through the back of the board and the mount

-

ing bracket. Check for loose connections at the terminals. Check for voltage across the inlet valve 

terminals. If there is 110 to 120 volts present at the inlet valve terminals when water level is touching 

the probe tip, replace the L.L.C. board.

1.  Defective water inlet 

valve

2.  Liquid level probe 

limed up

3.  Non-grounded or loose 

terminal connections 

at liquid level control 

board

TROUBLE SHOOTING

POSSIBLE CAUSE

SOLUTION

PROBLEM: WATER WILL NOT REFILL

1.  Water line closed or 

clogged filter

2.  Valve coil burned out

3.  Grounded probe

4.  Defective water level 

control board

Check the water system at your facility to make sure the line is open. Replace the water filter.

Turn machine off. Disconnect wires from water inlet coil terminals and connect a power cord to 

the terminals. Plug cord into a 120V outlet and verify if water flows when plugged in and stops 

when power is disconnected. If valve fails this test, replace valve.

When the water level gets below the probe tip, water should automatically refill the unit. If not, pull 

wire off the probe terminal. Water should now start flowing into the water boiler.

Disconnect wire from probe terminal. With a voltmeter, check voltage at the water inlet coil termi

-

nals. This should read 110-120 volts. If no voltage is present, check liquid level control (L.L.C.) 

board. Make sure the L.L.C. board is supplied by 120V across terminals 

NEU

 and 

L1 120V

. The 

L.L.C. board is grounded to the body of the machine by contacting the board to the mounting 

bracket. Make sure board is grounded here. Check for loose connections at terminals. Replace 

the L.L.C. board.

POSSIBLE CAUSE

SOLUTION

1.  Thermostat  is turned 

OFF (or set too low)

Check the thermostat adjustment to make sure the knob is rotated clockwise to the desired tem

-

perature setting.

PROBLEM: WATER DOES NOT REACH PROPER TEMPERATURE

SOLUTION

POSSIBLE CAUSE

PROBLEM:  WATER OVERHEATS, ELEMENTS DO NOT SHUT OFF

Replace the thermostat. You can sometimes operate temporarily by turning the thermostat knob 

to off until the boiling stops.

1.  Defective thermostat

4

Summary of Contents for WB-14-12

Page 1: ...LATION This Curtis unit is pre set and ready to go from the factory System Requirements Water Supply 20 90 PSI Min Flow Rate 2 gpm Electrical Refer to Electrical Schematic Factory Settings Water Temperature 200ºF Water Volume 14 Gallons NOTE A water filtration system must be used to help maintain trouble free operation In areas with extremely hard water we highly recommend the use of a Curtis appr...

Page 2: ...CTRIC THERMOSTAT VALVE INLET BRASS 50 GPM 120V 10W FOR WB 14 12 VALVE INLET BRASS 50 GPM 220V 10W FOR WB 14 60 REPAIR KIT INLET VALVE KIT HEATING ELEMENT 3 5KW 220V W JAM NUTS SLCN WSHRS THERMOMETER DIAL RU S Parts List Setup Steps Continued 3 Connect the water line to the water inlet fitting on the rear of the unit Water volume going to the machine should be consistent Use tubing sized sufficient...

Page 3: ...Illustrated Parts List 3 1 2 3 4 5 6 7 8 9 10 11 19 19A 13 14 15 12 16 17 18 20 21 22 ...

Page 4: ...lace the water filter Turn machine off Disconnect wires from water inlet coil terminals and connect a power cord to the terminals Plug cord into a 120V outlet and verify if water flows when plugged in and stops when power is disconnected If valve fails this test replace valve When the water level gets below the probe tip water should automatically refill the unit If not pull wire off the probe ter...

Page 5: ...ion Pull off the knob 2 Locate the tiny adjustment screw inside the stem see figure 1 Using a small screw driver adjust the temperature up or down a By turning the screw turn to the left will increase the temperature about 20 F b Turning to the right will decrease the temperature by 20 F c To set the thermostat precisely at 200 F insert a thermometer probe into the water jacket through the steam h...

Page 6: ...Electrical Diagram WB 14 12 6 ...

Page 7: ...Electrical Diagram WB 14 60 7 ...

Page 8: ...per voltage Equipment must be installed at the voltage stated on the serial plate supplied with this equipment 4 Improper water supply This includes but is not limited to excessive or low water pressure and inadequate or fluctuating water flow rate 5 Adjustments and cleaning The resetting of safety thermostats and circuit breakers programming and temperature adjustments are the responsibility of t...

Reviews: