background image

2

 1

 2

 3
 4
 5
 6
 7
 8

 9
10

11

12

13
14
15
16
17
18

19
19A
20
21
22

DESCRIPTION

PART №

ITEM

WC-5602
WC-6118-01
WC-4303

WC-5335

WC-5502-01
WC-5510
WC-2401
WC-3528

WC-5334

WC- 501
WC-  608-101
WC-2100
WC-2005
WC-2024
WC-2006
WC-3705
WC-1800HW
WC-3217
WC-  801

WC-  858

WC-3700
WC-  922-04

WC- 511

LID, 6 GAL WITH KNOB

COLLAR, TOP

O-RING, LINERS RU
TUBING, 8” WATER INLET
PROBE, WATER LEVEL
COVER, PROBE WA WB14
ELBOW, 3/8 NPT X 1/4 FLARE PLATED
LEG, 4” ADJUSTABLE 3/8-16 THREAD ITALIAN STYLE
TUBING, 15-1/2” WATER INLET
KIT, THERMOSTAT WB-14
CONTROL BOARD, LIQUID LEVEL 120/240VAC
GAUGE GLASS ASSY, 7”
WASHER, 1/8” SHIELD CAP
GLASS, GAUGE 7”
WASHER, 3/16” SHIELD BASE
REPAIR KIT, S FAUCET
FAUCET, S’ SERIES H/W
KNOB, ELECTRIC THERMOSTAT
VALVE, INLET BRASS ½.50 GPM 120V 10W FOR WB-14-12
VALVE, INLET BRASS .50 GPM 220V 10W FOR WB-14-60
REPAIR KIT, INLET VALVE
KIT, HEATING ELEMENT 3.5KW 220V W/JAM NUTS & SLCN WSHRS
THERMOMETER, DIAL RU’S

Parts List

Setup Steps Continued

3.  Connect the water line to the water inlet fitting on the rear of the unit. Water volume going to the machine should be consistent. 

Use tubing sized sufficiently to provide a minimum flow rate of two gallons per minute.

4. Connect the unit to electrical outlet with appropriate amperage rating  (refer to schematic for power requirements). 
5. Turn on the circuit running power to unit. The water inlet valve will open, filling the unit. When the boiler has filled,   turn on 

boiler at the thermostat, twisting the knob clockwise.

6. Heating tank will require 50 to 60 minutes to attain operating temperature. Thermostat indicator will light at this time.

Summary of Contents for WB-14-12

Page 1: ...LATION This Curtis unit is pre set and ready to go from the factory System Requirements Water Supply 20 90 PSI Min Flow Rate 2 gpm Electrical Refer to Electrical Schematic Factory Settings Water Temperature 200ºF Water Volume 14 Gallons NOTE A water filtration system must be used to help maintain trouble free operation In areas with extremely hard water we highly recommend the use of a Curtis appr...

Page 2: ...CTRIC THERMOSTAT VALVE INLET BRASS 50 GPM 120V 10W FOR WB 14 12 VALVE INLET BRASS 50 GPM 220V 10W FOR WB 14 60 REPAIR KIT INLET VALVE KIT HEATING ELEMENT 3 5KW 220V W JAM NUTS SLCN WSHRS THERMOMETER DIAL RU S Parts List Setup Steps Continued 3 Connect the water line to the water inlet fitting on the rear of the unit Water volume going to the machine should be consistent Use tubing sized sufficient...

Page 3: ...Illustrated Parts List 3 1 2 3 4 5 6 7 8 9 10 11 19 19A 13 14 15 12 16 17 18 20 21 22 ...

Page 4: ...lace the water filter Turn machine off Disconnect wires from water inlet coil terminals and connect a power cord to the terminals Plug cord into a 120V outlet and verify if water flows when plugged in and stops when power is disconnected If valve fails this test replace valve When the water level gets below the probe tip water should automatically refill the unit If not pull wire off the probe ter...

Page 5: ...ion Pull off the knob 2 Locate the tiny adjustment screw inside the stem see figure 1 Using a small screw driver adjust the temperature up or down a By turning the screw turn to the left will increase the temperature about 20 F b Turning to the right will decrease the temperature by 20 F c To set the thermostat precisely at 200 F insert a thermometer probe into the water jacket through the steam h...

Page 6: ...Electrical Diagram WB 14 12 6 ...

Page 7: ...Electrical Diagram WB 14 60 7 ...

Page 8: ...per voltage Equipment must be installed at the voltage stated on the serial plate supplied with this equipment 4 Improper water supply This includes but is not limited to excessive or low water pressure and inadequate or fluctuating water flow rate 5 Adjustments and cleaning The resetting of safety thermostats and circuit breakers programming and temperature adjustments are the responsibility of t...