background image

Service Manual – Combo Brewer

Tea Dilut. Volume

Tea Dilut. Time

Tea Dilut. Delay

Tea By Volume

Tea By Time

Tea by Volume

: Scroll until Brew by Volume is displayed. Press 

 to Select.  The display will read Select Brew But-

ton!  Once the desired brew button is selected (COFFEE or TEA), the display will read Press BREW to Start   0:00 Time. 

Press the FULL BREW button and hot water starts dispensing.  When the desired volume is reached, press FULL BREW 

again to stop the flow.  The brew volume has now been set (HALF BREW will always be half of the FULL BREW volume).  

When EXIT is displayed, Press 

 to select and exit the programming mode. Pressing > button will display the subse

-

quent menu features. 

Tea by Time

. (Factory set to 5:50) Press

 

 

to Select. Press < or >  to increase or decrease time. Tea by Time has a 

range of 0:00 to 9:59 (Increments are minutes and seconds). The HALF BREW button will be set at half the brew time.

Dilution Delay

: Press

 

 

to Select. Press < or >  to toggle between Standard-Gray (30 sec), Standard-Purple (30 sec), 

Tropical-Gray (9 min), Tropical-Purple (9 min), 76/308-Gray (4 min) and 76/308-Purple (4 min).  Range is from 0 seconds, 

1 minute to 10 minutes.

Dilution Volume

: Press 

 to Select, Display will now show Push START To Begin... Press the BREW button then water 

starts running, when desired volume is reached press BREW button again to stop the flow. Now the volume has been set. 

Pressing > button will display the subsequent menu features.

Dilution Time

: Press

 

 

to Select. Press < or >  to toggle between Standard-Gray (4min-5sec), Standard-Purple (4min-

5sec), Tropical-Gray (4min-26sec), Tropical-Purple (4min-26sec), 76/308-Gray (4min-55sec) and 76/308-Purple (4min-

55sec). Dilution Time is from 30 sec to 9 min, 59 sec. 

Tea Dilution Stir 

(Factory set to Standard – Purple On).

Press 

 to Select, press < or >  for a choice of Standard-Gray: On, Standard-Purple: On, Tropical-Gray-Off, Tropical-

Purple-Off, 76/308-Gray-Off and 76/308-Purple-Off. Dilution Stir applies only to the Dilution cycle, by pulsing the dilution 

time 45 seconds on, 5 seconds off.

Tea Pulse Brew 

(Factory set to OFF).

Press 

 to Select, press < or >  to choose ON/OFF or D (manual programming). D will give you a pulsing spray of 1-20 

pulses on and off at 5 second increments, depending on the total time set for brew (see Tea by Time).

Tea Fast Brew 

(Factory set to OFF).

Press 

 to Select, press < or >  to choose ON or OFF. Selecting ON will start hot water spraying in the brewcone first 

and then 1 minute later the dilution water will start to flow. 

Coffee by Volume

: Press 

 to Select, Display will now show Push START To Begin... Press the FULL BREW  button 

then hot water starts running, when desired volume is reached press FULL BREW  button again to stop the flow. Now the 

volume has been set (HALF BREW will always be half of the FULL BREW volume). 

Next item in the sequence is 

Coffee by Time

 (Factory set to 2min-25sec). Press 

 to Select to change the brew time. 

Display will now show the current time. By pressing < or > you can toggle back and forth from minutes to seconds to exit 

(ex). Change the time or set and exit by pressing 

Pre-Infusion

 (Factory set to OFF)

Press 

 to Select. Current setting in seconds is displayed  < to decrease or select  >  to increase (range from OFF to 10 

through 60 seconds), 

 to set. 

If Pre-infusion is selected (ON), Cold Brew Lock is set to Delta 1 within 5ºF of set point and Cold Brew Lock disappears 

from the list of program selections. When Pre-infusion  is ON, Pulse Brew disappears from the list of program selections. 

Pulse Brew

 (Factory setting OFF)

Press 

 to select, < or > to select OFF or one of five pulse patterns (A to E) .

Guidelines for Pulse Brew:

This feature allows tuning of the coffee flavor. This option should only be used with the standard Gray or Purple AFS 

sprayheads. The pot level should always be set first with this option OFF. Depending on your grind profile and water 

Tea Dilution Stir

Coffee By Time

Coffee By Volume

Coffee Pre-infusion

Tea Pulse Brew

Tea Fast Brew

Coffee Pulse Brew

Continued on Page 10

9

Summary of Contents for PTT3

Page 1: ...n In areas with extremely hard water we suggest that a sedimentary and taste odor filter be installed This will prolong the life of your brewing system and enhance coffee quality 1 A 1 4 Flare has been supplied for water line connection Use tubing sized sufficiently to provide GPM preferred flow rate is 1gpm 2 Connect the unit to an appropriate electrical power circuit 3 Turn on the toggle STANDBY...

Page 2: ...reen It takes approximately 20 minutes to reach set point temperature of 204 F Control will display when temperature reaches the set point 204 F Unit is now ready to brew CURTIS TCT CURTIS CURTIS FILLING CURTIS HEATING CURTIS READY to BREW Program Menus Tea By Volume Tea Recipes Tea By Time Program Menus screen Press button to show the next menu item Tea Recipes Factory set to Standard Tea Purple ...

Page 3: ... Select Shows total gallons and total brew cycles on the unit Not resettable Brew Count Total Press to Select Shows total gallons and total brew cycles on the unit Not resettable Cold Brew Lock Factory set to 5º F Press to select or to select desired setting CBL 5 15 or OFF to set The Cold Brew Lock feature allows the brewer to brew at three different temperature levels from the actual set point T...

Page 4: ...ONE BREW CONE W HANDLE 8 8 D W STRNR OPTIONAL HANDLE BREW CONE BLACK FOR WC 3320 KIT BREW CONE GOURMET PLASTIC ICED TEA BREWCONE W WC 3320 WC 3301 WC 3647 OPTNL BREWCONE ASSY PARADISE TEA OPTIONAL KIT BREW CONE BLK PLASTIC PARADISE TEA ONLY COVER TOP BREWER FITTING SPRAYHEAD ULTEM UCM KIT LABEL OVERLAY 120V TCTS T KIT UCM OVERLAY W HALF BATCH BREW TCTS LABEL UCM PANEL TCT PTT GT3 W O FAUCET CURTIS...

Page 5: ...OLD UNIT WITH EZ VIEW 1 2 3 4 5A 10 11 12 14 36 35 21 13 38 37 27 6 7 8 9 5 5C 34 32 18A 18 19 23 24 25 26 15 16 17 16A 33 28 29 5B 22 20 30 31 Service Manual Tea Brewer 5 ...

Page 6: ...7 8 9 10 WC 61436 WC 38471 WC 1803 WC 37260 WC 3707 WC 1805 WC 38163 WC 5686 WC 3531 WC 3289 LID BLACK PLASTIC TCN LABEL FRONT TCN GENERIC FAUCET SPB KIT FAUCET W ADAPTER CMPLT KIT REPAIR SPB FAUCET SEAT CUP FAUCET S LABEL CURTIS SWP CLR WHT DRIP TRAY OCTAGON STYLE LEG PLASTIC GLIDE TCN HANDLE GASKET DESCRIPTION PART Nº ITEM ...

Page 7: ... tubing sized sufficiently to provide a minimum of gpm 1 gpm is preferred 2 Connect the unit to an appropriate electrical power circuit 3 Turn on the toggle STANDBY ON switch behind the unit The heating tank will start to fill When the water level in the tank rises to the correct volume the heating element will energize automatically With the G3 Gold Cup Series there is no danger of element burnou...

Page 8: ... a beep sound indicating power is available to the controller The control displays Press ON OFF button and the screen will display After three seconds is displayed Water will fill the tank approximately 2 3 minutes depending on water flow rate When the proper level is reached will appear on the screen It takes approximately 20 minutes to reach set point temperature of 204 F Control will display wh...

Page 9: ... and 76 308 Purple Off Dilution Stir applies only to the Dilution cycle by pulsing the dilution time 45 seconds on 5 seconds off Tea Pulse Brew Factory set to OFF Press to Select press or to choose ON OFF or D manual programming D will give you a pulsing spray of 1 20 pulses on and off at 5 second increments depending on the total time set for brew see Tea by Time Tea Fast Brew Factory set to OFF ...

Page 10: ... Cold Brew Lock Factory set to 5º Press to select or to select desired setting CBL 5 15 or OFF to set The Cold Brew Lock feature allows the brewer to brew at three different temperature levels from the actual set point The first setting is within 5 degrees of set point next is within 15 degrees of set point OFF is within 30 degrees of set point for the Ready to Brew message however it will brew at...

Page 11: ...ay ON or OFF Pressing either or toggles between on and off Safety Sw On Off Factory set to ON Press to display ON or OFF Pressing either or toggles between on and off to set When this feature is turned OFF the tea brewing safety switch is by passed You may brew tea without having to depress the switch Exit Press to select exits program mode and returns unit to operation Pressing returns you to Bre...

Page 12: ...10 11 12 14 52 50 49 27 13 51 28 6 7 8 9 18 18A 22 19 21 23 24 25 26 12A 15 16 37 38 39 40 41 42 43 5 5A 44 45 46 47 48 A B A B Service Manual Combo Brewer 12 Illustrated Parts List Curtis Combo Coffee Tea Brewer ...

Page 13: ...UTS SHOCK GUARD HEATING ELEMENT SENSOR TEMPERATURE TANK THERMOSTAT MANUAL RESET 120 220V 25A 220ºF MAX DESCRIPTION PART Nº ITEM 27 28 29 29A 29B 29C 30 31 32 33 34 35 36 37 38 38A 39 39A 40 41 42 43 44 45 46 47 48 49 50 51 52 WC 5231 WC 5310 TCO308A000 TCO417A000 TCO419A000 TCO421A000 WC 5683 WC 38471 WC 3724 WC 1803 WC 3707 WC 1805 WC 37260 WC 1809 WC 61709 WC 61708 WC 4538 WC 4526 WC 169 WC 3827...

Page 14: ...803 WC 37260 WC 3707 WC 1805 WC 38163 WC 5686 WC 3531 WC 3289 LID BLACK PLASTIC TCN LABEL FRONT TCN GENERIC FAUCET SPB KIT FAUCET W ADAPTER CMPLT KIT REPAIR SPB FAUCET SEAT CUP FAUCET S LABEL CURTIS SWP CLR WHT DRIP TRAY OCTAGON STYLE LEG PLASTIC GLIDE TCN HANDLE GASKET DESCRIPTION PART Nº ITEM ...

Page 15: ...ng hot liquid over the unit CAUTION DO NOT use undiluted bleach or chlorine TEA TIPS 1 Store tea bags in a dark cool and dry place away from strong odors and moisture Do not refrigerate 2 Never hold finished brewed tea for more than eight hours at room temperature Discard any unused tea after eight hours 3 Brew only enough tea that you reasonably expect to sell within a few hours 4 To protect tea ...

Page 16: ...oltage stated on the serial plate supplied with this equipment 4 Improper water supply This includes but is not limited to excessive or low water pressure and inadequate or fluctuating water flow rate 5 Adjustments and cleaning The resetting of safety thermostats and circuit breakers programming and temperature adjustments are the responsibility of the equipment owner The owner is responsible for ...

Reviews: