16A
17
18
18A
19
20
21
22
22A
23
24
25
26
27
28
29
30
31
32

33

34

35
36
37

38

WC-3503
WC-8531
WC-5853-102
WC-5851
WC-43062
WC-6277
WC-5231*
WC-37278
WC-5502-01*
WC-  904-04*
WC-4394
WC-1438-101*
WC-  523*
WC-5310*
WC-5683
WC-38471
WC-3724*
WC-1803
WC-1805*
WC-3707*
WC-37260*
WC-2707
WC-53038
WC- 826L*
WC- 801*

LEG, 8-32 STD SCREW BUMPER
RAIL, BASE TCTD
COVER, TOP HEATING TANK GEN USE
COVER, TANK W NOTCHES (OLDER UNITS)
GASKET, TANK LID
TANK ASSY, COMPLETE TEA BREWER
COMPOUND SILICONE 5 OZ
KIT, LIQUID LEVEL PROBE GT
PROBE ASSY, W/HEX FTNG, O’RNG, NUT (OLDER UNIT)
ELEMENT, HEATING 1.6KW 120V W/JAM NUTS
SHOCK GUARD, HEATING ELEMENT
SENSOR, TEMPERATURE TANK
THERMOSTAT, MANUAL RESET 120/220V 25A 220ºF MAX
 TUBING, 5/16” ID X 1/8” W SILICONE
LID ASSY, TCO
LABEL, FRONT ICED TEA GENERIC
KIT, EZ-VIEW REPLACEMENT (OLDER UNITS)
FAUCET, SPB
SEAT CUP, FAUCET S’
KIT, REPAIR SPB FAUCET
KIT, FAUCET W/ADAPTER COMPLETE
TEE, FLARE ¼ x ¼ x ⅜ BRASS
TUBE ASSY, FLEXIBLE 1/4 FLARE 11-1/8” 
VALVE, INLET 1 GPM 120V 10W  
VALVE, INLET BRASS .50 GPM 120V 10W RU/WB

DESCRIPTION

PART Nº

* Recommended parts to stock

PARTS LIST

ITEM

  1
  2
  2A

  3

  4

  5
  5A
  5B
  5C
  6
  7

  8
  8A
  9
  9A
10
10A
11
12
13
14
14A
14B
15
16

WC-3301
WC-3647
WC-8532
WC-3320
WC-3201
WC-37256
WC-3358
WC-33001
WC-37239
WC-58117
WC-2977-101
WC-37189*
WC-37338
WC-39398*
WC-39628
WC-29025*
WC-2942
WC-2965
WC-8556*
WC-2401
WC-58017
WC-58021
WC-58101
WC-  102*
WC-3518

BASKET, WIRE 7.00 DIA. USE WITH WC-3311 (OPTNL)
STRAINER BT-10 BREWCONE (EXCEPT PARADISE)
STRAINER, TROPICAL BREWCONE
BREW CONE W/HANDLE 8.8” D W/STRNR (OPTIONAL)
HANDLE, BREW CONE BLACK FOR WC-3320
KIT, BREW CONE GOURMET PLASTIC ICED TEA
BREWCONE W/WC-3320, WC-3301 & WC-3647 (OPTNL)
BREWCONE ASSY, PARADISE TEA (OPTIONAL)
KIT, BREW CONE BLK PLASTIC PARADISE TEA ONLY
COVER, TOP BREWER
FITTING, SPRAYHEAD ULTEM
UCM KIT, LABEL & OVERLAY 120V TCTS/T
KIT, UCM & OVERLAY W/HALF BATCH BREW TCTS
LABEL, UCM PANEL TCT/PTT GT3 W/O FAUCET CURTIS
LABEL, UCM PANEL W/HALF BATCH W/O FAUCET
SPRAYHEAD, PURPLE ADVANCE FLOW
SPRAYHEAD, GRAY (OLDER UNITS)
SPOUT, BYPASS ASSEMBLY
HEAT SINK ASSY DV
ELBOW, 3/8 NPT X 1/4 FLRE PLTD
COVER, CENTER WRAP TCT-35S TCTDP-35S
COVER, FRONT CENTER WRAP TCTT/TCTD-35S
COVER, CENTER WRAP SS PTT3
SWITCH, TOGGLE SPST 25A 125/250VAC RESISTIVE 
LEG, GLIDE 3/8”-16 STUD SCREW

DESCRIPTION

PART Nº

ITEM

Service Manual – Tea Brewer

P-Maintenance

Beeper On/Off

Exit

P-Maintenance 

(Factory set to OFF)

Press 

 to Select, Set gallons brewed to indicate P-Maintenance. Press  < or > to adjust from Off to 3000 gallons. 

Press 

 to exit.

Beeper On/Off 

(Factory set to ON)

Press 

 to display ON or OFF. Pressing either < or > toggles between on and off. 

 

to set. When ON, this feature 

allows you to hear a short beep each time a button is pressed.

Quality Timer 

(Factory set to OFF)

Press 

 to Select. By pressing < or > buttons, you can increase and decrease time. Setting range is from 0 to 10 

hours in 1 hour increments. Press 

 to set. Expired time indicated by audio alarm and flashing “Quality Timer”.

Display Brew Time 

(Factory set to ON)

Press 

 to Select. Pressing < or > toggles between ON and OFF. 

Exit

Press 

 to select, exits program mode and returns unit to operation. Pressing > returns you to Tea Recipes.

Quality Timer

Display Brew 

Time

4

Summary of Contents for PTT3

Page 1: ...n In areas with extremely hard water we suggest that a sedimentary and taste odor filter be installed This will prolong the life of your brewing system and enhance coffee quality 1 A 1 4 Flare has been supplied for water line connection Use tubing sized sufficiently to provide GPM preferred flow rate is 1gpm 2 Connect the unit to an appropriate electrical power circuit 3 Turn on the toggle STANDBY...

Page 2: ...reen It takes approximately 20 minutes to reach set point temperature of 204 F Control will display when temperature reaches the set point 204 F Unit is now ready to brew CURTIS TCT CURTIS CURTIS FILLING CURTIS HEATING CURTIS READY to BREW Program Menus Tea By Volume Tea Recipes Tea By Time Program Menus screen Press button to show the next menu item Tea Recipes Factory set to Standard Tea Purple ...

Page 3: ... Select Shows total gallons and total brew cycles on the unit Not resettable Brew Count Total Press to Select Shows total gallons and total brew cycles on the unit Not resettable Cold Brew Lock Factory set to 5º F Press to select or to select desired setting CBL 5 15 or OFF to set The Cold Brew Lock feature allows the brewer to brew at three different temperature levels from the actual set point T...

Page 4: ...ONE BREW CONE W HANDLE 8 8 D W STRNR OPTIONAL HANDLE BREW CONE BLACK FOR WC 3320 KIT BREW CONE GOURMET PLASTIC ICED TEA BREWCONE W WC 3320 WC 3301 WC 3647 OPTNL BREWCONE ASSY PARADISE TEA OPTIONAL KIT BREW CONE BLK PLASTIC PARADISE TEA ONLY COVER TOP BREWER FITTING SPRAYHEAD ULTEM UCM KIT LABEL OVERLAY 120V TCTS T KIT UCM OVERLAY W HALF BATCH BREW TCTS LABEL UCM PANEL TCT PTT GT3 W O FAUCET CURTIS...

Page 5: ...OLD UNIT WITH EZ VIEW 1 2 3 4 5A 10 11 12 14 36 35 21 13 38 37 27 6 7 8 9 5 5C 34 32 18A 18 19 23 24 25 26 15 16 17 16A 33 28 29 5B 22 20 30 31 Service Manual Tea Brewer 5 ...

Page 6: ...7 8 9 10 WC 61436 WC 38471 WC 1803 WC 37260 WC 3707 WC 1805 WC 38163 WC 5686 WC 3531 WC 3289 LID BLACK PLASTIC TCN LABEL FRONT TCN GENERIC FAUCET SPB KIT FAUCET W ADAPTER CMPLT KIT REPAIR SPB FAUCET SEAT CUP FAUCET S LABEL CURTIS SWP CLR WHT DRIP TRAY OCTAGON STYLE LEG PLASTIC GLIDE TCN HANDLE GASKET DESCRIPTION PART Nº ITEM ...

Page 7: ... tubing sized sufficiently to provide a minimum of gpm 1 gpm is preferred 2 Connect the unit to an appropriate electrical power circuit 3 Turn on the toggle STANDBY ON switch behind the unit The heating tank will start to fill When the water level in the tank rises to the correct volume the heating element will energize automatically With the G3 Gold Cup Series there is no danger of element burnou...

Page 8: ... a beep sound indicating power is available to the controller The control displays Press ON OFF button and the screen will display After three seconds is displayed Water will fill the tank approximately 2 3 minutes depending on water flow rate When the proper level is reached will appear on the screen It takes approximately 20 minutes to reach set point temperature of 204 F Control will display wh...

Page 9: ... and 76 308 Purple Off Dilution Stir applies only to the Dilution cycle by pulsing the dilution time 45 seconds on 5 seconds off Tea Pulse Brew Factory set to OFF Press to Select press or to choose ON OFF or D manual programming D will give you a pulsing spray of 1 20 pulses on and off at 5 second increments depending on the total time set for brew see Tea by Time Tea Fast Brew Factory set to OFF ...

Page 10: ... Cold Brew Lock Factory set to 5º Press to select or to select desired setting CBL 5 15 or OFF to set The Cold Brew Lock feature allows the brewer to brew at three different temperature levels from the actual set point The first setting is within 5 degrees of set point next is within 15 degrees of set point OFF is within 30 degrees of set point for the Ready to Brew message however it will brew at...

Page 11: ...ay ON or OFF Pressing either or toggles between on and off Safety Sw On Off Factory set to ON Press to display ON or OFF Pressing either or toggles between on and off to set When this feature is turned OFF the tea brewing safety switch is by passed You may brew tea without having to depress the switch Exit Press to select exits program mode and returns unit to operation Pressing returns you to Bre...

Page 12: ...10 11 12 14 52 50 49 27 13 51 28 6 7 8 9 18 18A 22 19 21 23 24 25 26 12A 15 16 37 38 39 40 41 42 43 5 5A 44 45 46 47 48 A B A B Service Manual Combo Brewer 12 Illustrated Parts List Curtis Combo Coffee Tea Brewer ...

Page 13: ...UTS SHOCK GUARD HEATING ELEMENT SENSOR TEMPERATURE TANK THERMOSTAT MANUAL RESET 120 220V 25A 220ºF MAX DESCRIPTION PART Nº ITEM 27 28 29 29A 29B 29C 30 31 32 33 34 35 36 37 38 38A 39 39A 40 41 42 43 44 45 46 47 48 49 50 51 52 WC 5231 WC 5310 TCO308A000 TCO417A000 TCO419A000 TCO421A000 WC 5683 WC 38471 WC 3724 WC 1803 WC 3707 WC 1805 WC 37260 WC 1809 WC 61709 WC 61708 WC 4538 WC 4526 WC 169 WC 3827...

Page 14: ...803 WC 37260 WC 3707 WC 1805 WC 38163 WC 5686 WC 3531 WC 3289 LID BLACK PLASTIC TCN LABEL FRONT TCN GENERIC FAUCET SPB KIT FAUCET W ADAPTER CMPLT KIT REPAIR SPB FAUCET SEAT CUP FAUCET S LABEL CURTIS SWP CLR WHT DRIP TRAY OCTAGON STYLE LEG PLASTIC GLIDE TCN HANDLE GASKET DESCRIPTION PART Nº ITEM ...

Page 15: ...ng hot liquid over the unit CAUTION DO NOT use undiluted bleach or chlorine TEA TIPS 1 Store tea bags in a dark cool and dry place away from strong odors and moisture Do not refrigerate 2 Never hold finished brewed tea for more than eight hours at room temperature Discard any unused tea after eight hours 3 Brew only enough tea that you reasonably expect to sell within a few hours 4 To protect tea ...

Page 16: ...oltage stated on the serial plate supplied with this equipment 4 Improper water supply This includes but is not limited to excessive or low water pressure and inadequate or fluctuating water flow rate 5 Adjustments and cleaning The resetting of safety thermostats and circuit breakers programming and temperature adjustments are the responsibility of the equipment owner The owner is responsible for ...