Continued on Page 4
Service Manual – Tea Brewer
Tea Dilution Stir
(Factory set to ON).
Press
to Select. Press < or > buttons, to toggle between OFF and ON. Press
to set.
Tea Pulse Brew
(Factory set to OFF).
Press
to Select. Press < or > to select ON, OFF or D. D is a manual adjust from 1 to 20 pulses with an ON time
from 5 to 150 seconds and an OFF time from 5 to 150 seconds.
Tea Fast Brew
(Factory set to OFF).
Press
to Select, press < or > to choose ON or OFF. Selecting ON will start hot water spraying in the brewcone first
and then 1 minute later the dilution water will start to flow.
Tea Half Batch
(Factory set to OFF).
Press
to Select.
Press < or > buttons, to toggle between OFF and ON. Press
to set.
Drip-Out
(Factory set to 45 seconds)
Press
to Select. Press < or > to adjust time. Settings are OFF, up to 15 minutes, at one minute increments.
Temperature
(Factory set to 204
ºF
)
Press
to Select. Press < or > to increase or decrease setting. Temperature range,
from 170ºF to 208ºF in 2-degree
increments.
Energy Save Mode
(Factory set to OFF)
Press
to Select, < or > ON, OFF or ON 140ºF ,
to set. When in ON, unit will automatically shut off 4 hours from
last brew. When feature is OFF, unit does not have the energy saving mode.
In the ON 140ºF position, temperature goes down to 140ºF. if unit has not brewed in 4 hours. This feature will save
energy by maintaining a lower temperature in the tank during periods of non-operation.
Brew Count Odom.
Press
to display total brew cycles. Press ex or Reset Brew Count Total
Press
to Select, Shows total gallons and total brew cycles on the unit. Not resettable.
Brew Count Total
Press
to Select, Shows total gallons and total brew cycles on the unit. Not resettable.
Cold Brew Lock
(Factory set to 5º F)
Press
to select, < or > to select desired setting (CBL 5, 15 or OFF),
to set.
The Cold Brew Lock feature allows the brewer to brew at three different temperature levels from the actual set point.
The first setting is within 5 degrees of set point, next is within 15 degrees of set point, OFF is within 30 degrees of
set point for the Ready to Brew message, however it will brew at any temperature.
Master Reset
Press
to display Are You Sure? Then < for Yes, > for No. When Master Reset is used, the all of the menu selec
-
tions in the UCM return to factory defaults.
Service Call
(Phone number Factory set to [800] 995-0417)
Press
to display number and change number or < to move place and EX to exit when complete. This number will
be displayed during a Heating system SENSOR ERROR or during a WATER ERROR.
Access Code
(Factory set to 1-2-3-4)
Press
to display number and change number, (the number can be changed 1 to 4) or < to move place and ex to exit
when complete.
Banner Name
(Factory set to CURTIS)
Press
to display letters and change letters or < to move place and EX to exit when complete
This feature allows up to 14 letters to be programmed for company name or regional name. Programming all blanks
disables Banner Name. If programmed, Banner Name is displayed every 5 sec. on and off.
Temperature
Tea Dilut Stir
Energy Save Mode
Brew Count Odom
Master Reset
Service Call
Brew Count Total
Cold Brew Lock
Tea Pulse Brew
Access Code
Tea Fast Brew
Banner Name
Tea Half Batch
Drip-Out