background image

2

3

1. TECHNICAL SPECIFICATIONS

1.1 Electrical:

Wiring

The Model FP-10 has a 1 meter long, nine circuit 

cable for ease of wiring into any system. The wiring 

assignment of the FP-10 is shown in Table 1:

Signal Name

Wire Color

POT Low

Black

POT Wiper

White

POT High

Red

Neutral Switch 

Green

Neutral Switch 

Blue

Full Throttle Switch 

Yellow

Full Throttle Switch 

Brown

Spring 1 Detect Switch

Orange

Spring 2 Detect Switch

Purple

Potentiometer

Resistance: 5kΩ ± 10%

Power Rating: 2W max.

Rotational cycles: +1,000,000

Neutral & Full Throttle Switches

Type: SPST – NO

Current Rating: 10A @ 30Vdc (resistive load)

Voltage Rating: 250V

Spring Detect Switches

Type:  SPST – NC

Current Rating: 20mA

Voltage Rating: 15V

Table 1: Wire Assignments

Pedal 

Position

Angle in 

degrees

Switch #1 

(Neutral)

Switch #2 

(Full Throttle)

Pot Output 

(Ohms)

A

Open

Open

< 10

B

4° ±1°

Closed

Open

100 – 400

C

26° ±1°

Closed

Closed

4.5K – 5.0K

D

30° ±3° 

Closed

Closed

4.5K – 5.5K

Table 2: Operating Specifications

Summary of Contents for FP-10

Page 1: ...MODEL FP 10 Read Instructions Carefully CURTIS INSTRUMENTS INC 200 Kisco Ave Mount Kisco New York 10549 914 666 2971 www curtisinstruments com 53090 Rev B 6 18...

Page 2: ...lation and startup must be performed by skilled personnel Failure to install and operate the unit in accordance with these instructions may result in damage or injury If safe operation of the product...

Page 3: ...g 1 Detect Switch Orange Spring 2 Detect Switch Purple Potentiometer Resistance 5k 10 Power Rating 2W max Rotational cycles 1 000 000 Neutral Full Throttle Switches Type SPST NO Current Rating 10A 30V...

Page 4: ...in both directions 18 shocks in total 500 m s 11ms half sine wave location 3 1 2 Mechanical The molded housing is a glass filled nylon 6 6 It is sealed to IP 67 Refer to Outline Installation Drawings...

Page 5: ...the shaft at any angle Maximum tightening torque not to exceed 7 8 Nm 70 in lbs 6 For safety a mechanical stop between the angular position of 26 and 30 of travel should be used if a maximum normal f...

Page 6: ...9 1 000 150 0 Pedal Travel Angle SEE TABLE 2 A C B Pedal Initial Position D 153 0 MAX 140 0 70 0 5 0 61 128 5 50 0 SEE NOTE 8 0 0 104 0 123 0 8 5 80 0 40 0 66 5 0 5 8 5 0 5 0 0 FP 10 Dimensions cont...

Page 7: ...of pedal resistance of more than 50 indicates a single spring failure Return spring failure detection switches monitor each return spring and allow the vehicle designer to signal the user of a potent...

Page 8: ...cation thereby ensuring that it lasts for the life of the vehicle The FP 10 is supplied with a 1 meter length cable which is terminated in flying leads and a loose foot pedal For safety a mechanical s...

Page 9: ...reement as to any Curtis Instruments product and or component Curtis Instruments Inc cannot assume responsibility or accept invoices for unauthorized repairs to its products and or components even tho...

Reviews: