background image

TABLE OF CONTENTS

1. Technical Specifications 

 

 

1.1 Electrical 

  2 

 

1.2 Mechanical 

  4 

 

1.3 Environmental 

  5

2. Installation 

  6

3. Operation 

  11

4. Maintenance 

  13

5. Warranty 

  14

SAFETY INSTRUCTIONS

This product was manufactured and tested according to the 

applicable technical standards. It complies with all the safety 

regulations as shipped from the factory.

Installation and startup must be performed by skilled 

personnel.

Failure to install and operate the unit in accordance with these 

instructions may result in damage or injury.

If safe operation of the product can no longer be ensured, stop 

and secure it against accidental operation.

If product failure or malfunction may cause personal injury or 

material damage, use additional safety measures such as limit 

switches, guards, etc.

Read the Operating Instructions carefully before startup.

Note the safety instructions marked with this  

warning symbol in this manual!

Summary of Contents for FP-10

Page 1: ...MODEL FP 10 Read Instructions Carefully CURTIS INSTRUMENTS INC 200 Kisco Ave Mount Kisco New York 10549 914 666 2971 www curtisinstruments com 53090 Rev B 6 18...

Page 2: ...lation and startup must be performed by skilled personnel Failure to install and operate the unit in accordance with these instructions may result in damage or injury If safe operation of the product...

Page 3: ...g 1 Detect Switch Orange Spring 2 Detect Switch Purple Potentiometer Resistance 5k 10 Power Rating 2W max Rotational cycles 1 000 000 Neutral Full Throttle Switches Type SPST NO Current Rating 10A 30V...

Page 4: ...in both directions 18 shocks in total 500 m s 11ms half sine wave location 3 1 2 Mechanical The molded housing is a glass filled nylon 6 6 It is sealed to IP 67 Refer to Outline Installation Drawings...

Page 5: ...the shaft at any angle Maximum tightening torque not to exceed 7 8 Nm 70 in lbs 6 For safety a mechanical stop between the angular position of 26 and 30 of travel should be used if a maximum normal f...

Page 6: ...9 1 000 150 0 Pedal Travel Angle SEE TABLE 2 A C B Pedal Initial Position D 153 0 MAX 140 0 70 0 5 0 61 128 5 50 0 SEE NOTE 8 0 0 104 0 123 0 8 5 80 0 40 0 66 5 0 5 8 5 0 5 0 0 FP 10 Dimensions cont...

Page 7: ...of pedal resistance of more than 50 indicates a single spring failure Return spring failure detection switches monitor each return spring and allow the vehicle designer to signal the user of a potent...

Page 8: ...cation thereby ensuring that it lasts for the life of the vehicle The FP 10 is supplied with a 1 meter length cable which is terminated in flying leads and a loose foot pedal For safety a mechanical s...

Page 9: ...reement as to any Curtis Instruments product and or component Curtis Instruments Inc cannot assume responsibility or accept invoices for unauthorized repairs to its products and or components even tho...