4
5
Chemical Resistance
• Engine Oil
• Diesel Fuel
• Hydraulic Fluid
• Ethylene Glycol
• Urea Nitrogen 46%
• Liquid Lime
• NPK Fertilizer
• Ammonia
• Calcium Chloride
Salt Spray
Designed to meet ASTM B117-09, 5% salt fog spray
solution at 35 degrees C for 96 hours.
Solar Radiation
Designed to meet UV exposure per ASTM G155 Cycle
7A – 0.55W/m^2 at 340nm for 500 hours 63C continuous
temperature, no water spray.
Shock
Designed to meet EN 60068-2-27: 3 shocks in all 3 axes
in both directions (18 shocks in total), 500 m/s², 11ms, half
sine wave location 3.
1.2 Mechanical
The molded housing is a glass filled nylon
6/6. It is sealed to IP-67. Refer to Outline &
Installation Drawings for detailed specifications. The
FP10 is designed to meet 1 million cycles of use.
1.3 Environmental
Temperature
Operating:
–
40°C to +85°C
Storage:
–
40°C to +85°C
Humidity
Soak:
Designed to meet EN 60068-2-78. Test Cab:
Damp Heat, Steady State, 10 days at 95% RH (±3%),
and 30°C.
Cyclic:
Designed to meet EN 60068-2-30. Test Db:
Damp Heat, Cyclic (12hr + 12hr cycle). Test method
variant 1. 6 cycles (each cycle is 24hrs), 90% RH.
Ingress Protection
Designed to meet EN 60529-IP67.