background image

4

5

Chemical Resistance

•  Engine Oil

•  Diesel Fuel

•  Hydraulic Fluid

•  Ethylene Glycol

•  Urea Nitrogen 46%

•  Liquid Lime

•  NPK Fertilizer

•  Ammonia

•  Calcium Chloride

Salt Spray

Designed to meet ASTM B117-09, 5% salt fog spray 

solution at 35 degrees C for 96 hours.

Solar Radiation 

Designed to meet UV exposure per ASTM G155 Cycle 

7A – 0.55W/m^2 at 340nm for 500 hours 63C continuous 

temperature, no water spray.

Shock

Designed to meet EN 60068-2-27: 3 shocks in all 3 axes 

in both directions (18 shocks in total), 500 m/s², 11ms, half 

sine wave location 3.

1.2 Mechanical

The molded housing is a glass filled nylon 
6/6. It is sealed to IP-67. Refer to Outline & 
Installation Drawings for detailed specifications. The 
FP10 is designed to meet 1 million cycles of use.

 

1.3 Environmental

Temperature

Operating:

 

40°C to +85°C 

Storage:

 

40°C to +85°C 

Humidity

Soak:

 Designed to meet EN 60068-2-78. Test Cab:  

Damp Heat, Steady State, 10 days at 95% RH (±3%), 

and 30°C.

Cyclic: 

Designed to meet EN 60068-2-30. Test Db: 

Damp Heat, Cyclic (12hr + 12hr cycle). Test method 

variant 1. 6 cycles (each cycle is 24hrs), 90% RH.

Ingress Protection

Designed to meet EN 60529-IP67.

Summary of Contents for FP-10

Page 1: ...MODEL FP 10 Read Instructions Carefully CURTIS INSTRUMENTS INC 200 Kisco Ave Mount Kisco New York 10549 914 666 2971 www curtisinstruments com 53090 Rev B 6 18...

Page 2: ...lation and startup must be performed by skilled personnel Failure to install and operate the unit in accordance with these instructions may result in damage or injury If safe operation of the product...

Page 3: ...g 1 Detect Switch Orange Spring 2 Detect Switch Purple Potentiometer Resistance 5k 10 Power Rating 2W max Rotational cycles 1 000 000 Neutral Full Throttle Switches Type SPST NO Current Rating 10A 30V...

Page 4: ...in both directions 18 shocks in total 500 m s 11ms half sine wave location 3 1 2 Mechanical The molded housing is a glass filled nylon 6 6 It is sealed to IP 67 Refer to Outline Installation Drawings...

Page 5: ...the shaft at any angle Maximum tightening torque not to exceed 7 8 Nm 70 in lbs 6 For safety a mechanical stop between the angular position of 26 and 30 of travel should be used if a maximum normal f...

Page 6: ...9 1 000 150 0 Pedal Travel Angle SEE TABLE 2 A C B Pedal Initial Position D 153 0 MAX 140 0 70 0 5 0 61 128 5 50 0 SEE NOTE 8 0 0 104 0 123 0 8 5 80 0 40 0 66 5 0 5 8 5 0 5 0 0 FP 10 Dimensions cont...

Page 7: ...of pedal resistance of more than 50 indicates a single spring failure Return spring failure detection switches monitor each return spring and allow the vehicle designer to signal the user of a potent...

Page 8: ...cation thereby ensuring that it lasts for the life of the vehicle The FP 10 is supplied with a 1 meter length cable which is terminated in flying leads and a loose foot pedal For safety a mechanical s...

Page 9: ...reement as to any Curtis Instruments product and or component Curtis Instruments Inc cannot assume responsibility or accept invoices for unauthorized repairs to its products and or components even tho...

Reviews: