background image

3

1

0

1

0

1

0

The following procedures (3.1.2 and 3.1.3) can be done without V+ applied to Setup
Enable pin. Press and hold the left button           on the front panel until the entire dis-
play flashes and then release.

3.1.2 Setting/Changing the Time-of-Day Clock

See Section 2.6.2.

3.1.3 Resetting the Maintenance Hour Meter

Press the left button          until the maintenance hour meter function is displayed
(the wrench icon will be illuminated). Press and hold both the right button       and
the left button          until the display flashes and the maintenance hour meter is
reset to zero. This can be performed at any time, independent of the actual
maintenance status.

3.2 Auto-range

Curtis enGage™ II will automatically recognize one of the following 4 battery volt-
ages: 12VDC or 36VDC - 24VDC or 48VDC based on the status of the auto-range
input pin.

3.3 Output and Warning LED

KEY: RMB = Right Most LCD Bar / LMB = Left Most LCD Bar

3.4 LCD Icons

Curtis enGage™ II contains a number of icons to assist the user:

a) Hourglass Icon - Turned on (not blinking) to indicate that an hour meter is

displayed in the numeric display. Flashes to indicate hour meter accumulation.

b) Wrench Icon - Turned on (not blinking) to indicate that the maintenance hour 

meter is displayed in the numeric display. Flashes when the maintenance 
interval is reached.

c) Colon - Flashes to indicate that the time-of-day clock is being displayed in the 

numeric display and that time is counting-up.

d) Decimal Point - To indicate 1/10 of an hour on the maintenance hour meter

e) Fuel or Battery Icon - Turned on (not flashing) depending on which function the

gauge is programmed to monitor. It flashes when a low condition is detected.

f) Percent - Indicates remaining percentage of interval or level.

3.5 Resetting BDI

OCR – Open Circuit Reset 

The BDI will reset when gauge is disconnected from discharged battery 
and reconnected to a fully charged battery.

CTR – Charge Tracking Reset

Battery state-of-charge will be tracked by gauge during charging period(s).

Function

LED Activated

FET Activated

Fuel

LMB

LMB

Temp

RMB

RMB

Pressure

LMB & RMB

LMB & RMB

Voltage

2nd LMB & RMB

2nd LMB & RMB

Tach

RMB

RMB

BDI

LMB

LMB

Maintenance Due

LMB

LMB

:

.

4.0 Troubleshooting

BDI Function

Problem

Possible Cause

No Display

Terminals not connected.
Improper voltage.

Stays At FULL

Instrument voltage does not match battery voltage.
V+ connected to wrong terminal.

Will Not Reset

Instrument voltage does not match battery voltage.
Battery not fully charged.
Battery may be defective.

Resets without Charging 

Not connected directly to battery terminal.

Battery

EMPTY Too Soon

V+ connected to wrong terminal.
Instrument voltage does not match battery voltage.
Terminals not directly connected to battery.

Will Not / Cannot Configure

Procedure in section 3.6.3 not being followed.
No power to Setup Enable pin.

Sender Function

Problem

Possible Cause

No Display

Terminals not connected.
Improper voltage.

Stays At FULL

V+ connected to wrong terminal.
Sender or sender connection problems.

EMPTY Too Soon

V+ connected to wrong terminal.
Sender or sender connection problems.

Maintenance Function

Problem

Possible Cause

Will Not Reset

Section 3.1.3 procedure not being followed.

5.0 Maintenance

The enGage™

II

3000 Series is not serviceable.