background image

2.3 Mounting

Caution! 
Bracket is placed over gauge in reverse fashion for ease of shipping. Bracket has
been designed to remain secured to the gauge upon proper installation. Once
installed correctly, attempts to remove bracket from gauge may result in damage to
the bracket.

See complete drawing with notes on reverse side of page.

Curtis enGage™ II instruments are mounted in a 52mm round cutout. Serrations on
the barrel of the gauge, combined with the mounting bracket provided, insure fast
and trouble free installation. To insure proper installation, the 2 locking tabs on
either side of the inner diameter of the bracket should aligned with the serrations on
the barrel of the gauge (see drawing above). Next, slide the bracket over the barrel
of the gauge and press it firmly against back of panel. You should hear the tab slid-
ing over the serrations.

2.4 Interconnect

Curtis enGage™ II mates with either an 8-pin Molex connector (Molex pins P/N 39-
00-0039 FOR #18-24 AWG P/N 39-01-2085) or an 8-pin AMP connector (AMP pins
P/N 770904-X FOR #18-24 AWG P/N 794821-1). A preassembled mating connector
kit (Curtis P/N 15369002=Molex , Curtis P/N 17633308-03=AMP) with crimp-connect
terminated wires (approx. 127mm in length) is also available.

2.5 Product Identification

2.5.1 Programmable Vs. Factory Set Instruments

Curtis enGage™ II gauges are
available with or without front panel
buttons. Gauges without buttons are
factory set and cannot be adjusted
in the field. Gauges with buttons
have field adjustable parameters and
can be programmed per section 2.6.

1

0

1

0

2.5.2 enGage™ II & Multifunction Design

Curtis enGage™ II products can be configured in a variety of ways to maximize
customer value and efficiency. Because of this feature, the instruction manual
covers a broad spectrum of products. Please note that some sections of the
instructions may refer to functions not included with your instrument.

2.6 Configuring Your Gauge

Access to these operations is sequential in this order. Adjustments of the following
functions can be performed in the Configuration Mode:
1. Time-of-Day Clock
2. Battery Discharge Indicator profiles
3. Maintenance interval 
4. Settable hour meter  

During configuration, the right button          is used to increment. The left button

is used to: 1. enter a selection; 2. advance to the next configurable item.

If no change is desired to a specific gauge function, continue to press the left button

until the next desired function is reached.

The time-of-day clock is entered by setting the hours digits between 01 and 12, then
"minutes" digits between "00" and "59".

The profile of the BDI is settable with the front panel buttons. The Discharge Full
profile (when the gauge will begin calculating ‘discharge’) is adjustable from 1.80
through 2.30 volts per cell (VPC) in 0.01 VPC increments. The Discharge Empty
profile (when the gauge will indicate ‘empty’) is adjustable from 1.50 through 2.20
VPC in 0.01 VPC increments.

The maintenance interval (when the gauge signals that maintenance is due) is
configurable and should be set after the initial installation. The interval can be set
between 1 and 9,999 hours in 1 hour increments.

The settable hour meter can be set to any value between 0 and 99,999 hours.
When the gauge is operational, the total hour meter will begin from this value.

Configuration Notes:
The gauge remains in configuration mode for 30 seconds without input from the
user.

When configuring each function (time-of-day, maintenance interval, etc.), you must
enter in all data for that function for it to be saved. If incomplete data is entered for
a function and the programming mode is timed out (after 30 seconds of no input
received by the gauge), the gauge will revert back to what was previously stored for
that item.

The gauge remains in configuration mode for 30 seconds without input from the
user.

When configuring each function (time-of-day, maintenance interval, etc.), you must
enter in all data for that function for it to be saved. If incomplete data is entered for
a function and the programming mode is timed out (after 30 seconds of no input
received by the gauge), the gauge will revert back to what was previously stored for
that item.

If you interrupt the data entry process in the Configuration Mode, the gauge saves
data in those sections already completed. To complete configuration, re-enter
configuration mode (2.6.1) and simply toggle past the completed sections and
resume where you left off.

2.6.1 Entering Configuration Mode

a) Apply main power (9-60VDC) to V+,  V-.
b) Apply V+ (9-60 VDC) to Keyswitch Input.
c) Apply V+ (9-60 VDC) to Set-up Enable.
d) Press and hold the left button           on the front panel until the entire display flashes 

and then release.

2.6.2 Setting the Time-of-Day Clock

The display will flash the two "Hours" digits. Press the right button

to increment by one hour, or hold the button to increment

continuously. When the desired number of hours is reached, press
the left button           once. The display will flash the two "Minutes"

digits. Press the right button          to increment by one minute or
hold the button to increment continuously. When the desired num-
ber of minutes is reached, press the left button           once.

2.6.3 Setting the Battery Indicator Profiles

The display will flash the three digits of the discharge full profile
(factory setting is 2.09 VPC). Press the right button          to
increment by 0.01 VPC or hold the button to increment
continuously. When the display reaches 2.30 it will automatically
restart at 1.80 VPC. When the desired reset profile setting is
reached, press the left button          once.

The display will flash the three digits of the discharge empty
profile (factory setting is 1.73 VPC). Press the right button
to increment by 0.01 VPC or hold the button to increment
continuously. When the display reaches full it will automatically
restart at 1.50 VPC. When the desired reset profile setting is
reached, press the left button          once.

2.6.4 Setting the Maintenance Interval

The display will flash the left digit (thousands of hours). Press
the right button          to increment by one or hold the button to
increment continuously. When the desired number is reached,
press the left button          once to proceed to the next digit.
Repeat this process for all 4 digits.

2.6.5 Setting the Total Hour Meter

The display will flash the left digit (tens of thousands of hours).
Press the right button         to increment by one or hold the but-
ton to increment continuously. When the desired number is
reached, press the left button           once to proceed to the next
digit. Repeat this process for all 5 digits.

2.6.6 Exiting Configuration Mode

The configuration mode can be exited in three ways:

a) Press and hold the left button          for three seconds.
b) Leave buttons untouched for 30 seconds.
c) Press the left button           after selecting the last (right) digit of the last function available.

3.0 Operation

When the main power (9-60 VDC) is applied to V+ and V-, a power-
up sequence is initiated. All display segments are illuminated for
one second. The display is then turned off until the keyswitch is
activated.

3.1 Button Use During Normal Operation

3.1.1 Toggling Display Functions

Press the left button           to sequentially toggle between the three numeric gauge
functions (time-of-day clock, maintenance hours, total hours).

1

0

2

page 4.