39
3-Way Valve Assembly
(INSTRUCTIONS FOR REBUILDING AND CLEANING)
1. Using a screwdriver, snap off the retaining clip, which secures the coil assembly.
2. Remove the retaining clip.
3. Slide the coil off the valve body, and using a spanner nut (P/N 62650-15), remove the core housing for cleaning or
rebuilding.
4. Clean all parts thoroughly, using a cleaning solvent.
5. When reassembling the valve, be sure that the body seal (“O” ring) is in place.
6. Tighten
gently.
7. Re-assemble coil assembly and retainer clip.
8. Remove red cap and push solenoid down. Then lift nameplate/retainer and push to remove.
9. Remove
solenoid.
10. Unscrew solenoid base sub-assembly or valve bonnet with special wrench adapter. Remove core assembly, core
spring, and solenoid base gasket from valve body.
11. All parts are now accessible to clean or replace. If parts are worn or damaged, install a complete ASCO Rebuild Kit
*
Indicates parts supplied in rebuild kit (P/N 62650-14).
Note: A spanner nut P/N 62650-15 will be needed for disassembling core
housing from body.