14
Pump Calibration-
(For the Dyna-Jet Model L30
without
the Syncroflow System)
Before attempting to spray, the FMI pump must be calibrated to the proper flow rate setting. The
required flow rate is dictated by the information on the formulation manufacturer's label.
Calibration
is performed using the "Calibration Switch" located inside the pump enclosure, not from the
Remote Control Box.
CAUTION:
Using the Calibration Switch does not require having the Atomizer and Blower operating.
Once the switch is depressed liquid will be pumped into the atomizer!
WARNING
Always wear OSHA approved protective clothing, gloves,
safety goggles and respirator when handling any type of formulations. Take
precautions to avoid spills and do not allow the formulation to contact your skin.
In the event of an accident know the proper measures to take. Always follow the information
contained on the formulation manufacturer's label.
Calibration Steps:
1) Loosen the two locking knobs and position the indicator to the setting in the Flow Table below that
is closest to your desired output. Note: Tighten both locking knobs after adjusting the pump.
Leaving the locking knobs loose can allow the cylinder to move and damage the pump.
Flow Rate Table
DYNA-JET L30 (FMI Pump)
Flow oz/min (ml/min)
Pump Setting
5.0 (148)
2
9.0 (266)
4
12.5 (370)
6
14.0 (414)
7 (Max)
2) Remove the atomizer dust cover and disconnect the formulation delivery tube at the rear of the
atomizer. Connect the calibration tube to the formulation tube and place the end of the tube in a
beaker or graduated cylinder.
3) Add insecticide (or other formulation to be sprayed) to the Formulation Tank.
4) Turn ON the Master ON/OFF switch located inside the pump enclosure.
Locking Knob
FMI Pump
Summary of Contents for DYNA-FOG DYNA-JET L30 2 Series
Page 21: ... ...
Page 22: ...Terminal Strip Wire Connection Diagram 22 ...
Page 24: ......
Page 26: ... ...
Page 28: ...28 ...
Page 30: ...Pump Bracket Assembly L30 30 ...
Page 38: ......
Page 41: ...Pump Enclosure Wiring Diagram L30 41 ...
Page 42: ...Remote Control Box Schematic L30 Series 2 42 ...