background image

6

ITEM  PART № 

DESCRIPTION

15 

WC-6221 

SCREEN, DRIP TRAY SS (OPTIONAL)

16 

WC-3765L* 

KIT, VALVE REPAIR (INLET VALVE)

17 

WC-5853-102 

COVER, TOP HEATING TANK

17A  WC-5851 

LID, HEATING TANK (OLDER UNITS)

18 

WC-724 

CONTROL MODULE, ALPHA/AIRPOT 220V 16 X 2 LCD, 16 PIN

19 

WC-43062 

GASKET, TANK LID

20 

WC-5502-01*    KIT, PROBE WATER LEVEL, O’RING, NUT

21 

WC-917-04*   

HEATING ELEMENT, 1450W 120V W/JAM NUTS & WASHERS

21A  WC-922-04 

KIT, ELEMENT HEATING 3.5KW 220V W/JAM NUTS, WASHERS

22 

WC-523* 

THERMOSTAT, MANUAL RESET 120/ 240 VAC 25A 220º F MAX

22A  WC-522 

THERMOSTAT, HI LIMIT HEATER CONTROL DPST 277V 40A

23 

WC-6289 

HEATING TANK CMPLT, 120V W/HI-LMT

23A  WC-6267 

TANK, COMPLETE ALP-DS/GT 220V

24 

WC-102* 

SWITCH, TOGGLE SPST 25A 125/250VAC

24A  WC-103 

SWITCH, TOGGLE NON-LIT DPST 25A 125/250VAC RESISTIVE

25 

WC-5231* 

COMPOUND, SILICONE 5 OZ TUBE

26 

WC-1438-101*  SENSOR, TEMPERATURE TANK

27 

WC-3763* 

KIT, VALVE REPAIR (DUMP VALVE)

28 

WC-5310 

TUBING, SILICONE 5/16” ID

* Recommended Parts to Stock.

25

17

19

23

20

21

22

26

A

16

B

27

3

28

ILLUSTRATED PARTS 

Detail Bubbles

Summary of Contents for D60GT10

Page 1: ...left to right and front to back located on a solid counter top Connect a water line from the water filter to the brewer NOTE A water filtration system must be used to help maintain trouble free operat...

Page 2: ...he tank approximately 2 3 minutes depending on water flow rate When the proper level is reached will appear on the screen Approximately 20 minutes are required to reach the set point temperature Contr...

Page 3: ...ess display will now show the next feature During the actual brew cycle a 2 minute drip mode is added to the brew time The programmed water level compensates for back to back brewing Delta 3 to allow...

Page 4: ...the C pulse setting Of course any of the A B or C settings may be used to suit your taste profile There are two additional settings D and E that allow you to manually set the ON TIME pulses and OFF T...

Page 5: ...1 0 GPM 120V 9A WC 856 VALVE INLET 1 GPM 240V 10W 10 WC 5970 COVER BACK CTR WRAP ALPHA D60GT 11 WC 8591 CAPACITOR X2 USED ON ALL ADS MODELS 12 WC 29025 SPRAYHEAD PURPLE ADVANCE FLOW 13 WC 3518 LEG GL...

Page 6: ...T HEATING 3 5KW 220V W JAM NUTS WASHERS 22 WC 523 THERMOSTAT MANUAL RESET 120 240 VAC 25A 220 F MAX 22A WC 522 THERMOSTAT HI LIMIT HEATER CONTROL DPST 277V 40A 23 WC 6289 HEATING TANK CMPLT 120V W HI...

Page 7: ...7 ELECTRICAL SCHEMATIC...

Page 8: ...g using the cleaning solution Brush inside the brew cone with cleaning solution 3 Scrub the sprayhead area with a cleaner soaked cloth 4 Rinse the sprayhead area with a water soaked cloth removing any...

Page 9: ...riteTM scuff pad 6 If a residual white layer is still visible on the probe remove the probe and soak it in vinegar or a scale removing chemical Repeat this step until the white layer is removed Filter...

Page 10: ...eaning The resetting of safety thermostats and circuit breakers programming and temperature adjustments are the responsibility of the equipment owner The owner is responsible for proper cleaning and r...