background image

3

Pre-Infusion (Factory set to OFF)

Press 

 to Select. Current setting in seconds is displayed  < to decrease or select  >  to increase (range from OFF to 10 through 

60 seconds), 

 to set. 

If Pre-infusion is selected (ON), Cold Brew Lock is set to Delta 1 within 5ºF of set point and Cold Brew Lock is disappears 

from the list of program selections. When Pre-infusion  is ON, Pulse Brew disappears from the list of program selections. 

Quality Timer (Factory set to OFF)  

Press 

 to Select, < or  > OFF or  ON 20 minutes to 120 minutes in 10 minute increments. 

Press 

 to set. An audible alarm will sound when time is expired.

Brew Count Total 

Press 

 to Select, Shows total gallons and total brew cycles on the unit. Brew Count Total cannot reset.

Cold Brew Lock . . . (Factory set to 15º)

Press 

 to select,  < or > to select desired setting (CBL 5, 15 or OFF),

 to set.

Master Reset 

Press 

 to display Are You Sure? Then  < for Yes,  > for No. Brewer factory defaults are then reset.

Service Call (Phone number Factory set to 1-800-000-0000x)

 

Press 

 to display number and change number or  < to move place and EX to exit when complete This number will be displayed 

during a Heating system SENSOR ERROR or during a WATER ERROR.

Access Code (Factory set to 1-2-3-4)  

Press 

 to display number and change number, (the number can be change 1 to 4) or < to move place and ex to exit when com-

plete.

Banner Name (Factory set to Curtis)

Press 

 to display letters and change letters or < to move place and EX to exit when complete. This feature allows up to 14 letters 

to be programmed for company name or regional name. Programming all blanks disables Banner Name. If programmed, Banner 

Name is displayed every 5 sec. on and off.

P-Maintenance (Factory set to OFF)

Press 

 to Select, Set gallons brewed to indicate P-Maintenance. Press  < or > to adjust from Off to 3000 gallons. Press 

 to exit.

Brew Volume

Selecting Brew by Volume or Brew by Time depends on whether you know your brew time before starting. From Program Menus 

press > display will now show the next feature. 

During the actual brew cycle, a 2-minute drip mode is added to the brew time. The programmed water level compensates 

for back to back brewing Delta 3 to allow for an increase of water volume.

Brew by Volume (Factory set to 60 oz.) 

Press 

 to Select, Display will now show Push START To Begin... Press the BREW button then hot water starts running, when 

desired volume is reached press BREW button again to stop the flow. Now the volume has been set. Pressing > button will display 

the subsequent menu features. 

Brew by Time (Factory set to 2 min – 20 sec). 

Press 

 to Select to change the brew time. Display will now show the current time. By pressing < or > you can toggle back and 

forth from minutes to seconds to exit (ex). Change the time or set and exit by pressing 

Temperature (Factory set to 200°F) 

Press 

 to Select. Press < or >  to move to desired temperature and then 

 to set. Temperature is programmable from 170ºF to 

206ºF in 2-degree increments.

Energy Save Mode (Factory set to OFF)

Press 

 to Select, < or  > ON, OFF or  ON 140ºF, 

 to set. When in ON, unit will automatically shut off 4 hours from last brew. 

When feature is OFF, unit does not have the energy saving mode. In the ON 140ºF position, temperature goes down to 140ºF if 

unit has not brewed in 4 hours. This feature will save energy by lowering the tank temperature during periods of non-operation.

Brew Count Odom. 

Press 

 to display total gallons brewed. Press ex or Reset

PROGRAM MENUS

Model Select – Always perform this first. This feature re-sets all settings to the factory defaults.

Scroll through menu to Model Select. Choices are ALPHA-1, ALPHA-2, ALPHA-3/4/5, Airpot Brewer and Thermo-Alpha. 

Select only Thermo-Alpha.

The Cold Brew Lock feature allows the brewer to brew at three different temperature levels from the actual set point. The first 

setting is within 5 degrees of set point, next is within 15 degrees of set point, OFF is within 30 degrees of set point for the Ready 

to Brew message, however it will brew at any temperature. This feature will operate after initialization to set temperature after the 

rear standby toggle switch is reset to ON.

Summary of Contents for D60GT10

Page 1: ...left to right and front to back located on a solid counter top Connect a water line from the water filter to the brewer NOTE A water filtration system must be used to help maintain trouble free operat...

Page 2: ...he tank approximately 2 3 minutes depending on water flow rate When the proper level is reached will appear on the screen Approximately 20 minutes are required to reach the set point temperature Contr...

Page 3: ...ess display will now show the next feature During the actual brew cycle a 2 minute drip mode is added to the brew time The programmed water level compensates for back to back brewing Delta 3 to allow...

Page 4: ...the C pulse setting Of course any of the A B or C settings may be used to suit your taste profile There are two additional settings D and E that allow you to manually set the ON TIME pulses and OFF T...

Page 5: ...1 0 GPM 120V 9A WC 856 VALVE INLET 1 GPM 240V 10W 10 WC 5970 COVER BACK CTR WRAP ALPHA D60GT 11 WC 8591 CAPACITOR X2 USED ON ALL ADS MODELS 12 WC 29025 SPRAYHEAD PURPLE ADVANCE FLOW 13 WC 3518 LEG GL...

Page 6: ...T HEATING 3 5KW 220V W JAM NUTS WASHERS 22 WC 523 THERMOSTAT MANUAL RESET 120 240 VAC 25A 220 F MAX 22A WC 522 THERMOSTAT HI LIMIT HEATER CONTROL DPST 277V 40A 23 WC 6289 HEATING TANK CMPLT 120V W HI...

Page 7: ...7 ELECTRICAL SCHEMATIC...

Page 8: ...g using the cleaning solution Brush inside the brew cone with cleaning solution 3 Scrub the sprayhead area with a cleaner soaked cloth 4 Rinse the sprayhead area with a water soaked cloth removing any...

Page 9: ...riteTM scuff pad 6 If a residual white layer is still visible on the probe remove the probe and soak it in vinegar or a scale removing chemical Repeat this step until the white layer is removed Filter...

Page 10: ...eaning The resetting of safety thermostats and circuit breakers programming and temperature adjustments are the responsibility of the equipment owner The owner is responsible for proper cleaning and r...