Service Manual - Frozen Beverage Dispenser
TROUBLESHOOTING
REFRIGERANT SPECIFICATIONS
CFB2
CFB1
CFB3
For reference only. Check the serial number label on the product for the refrigerant specifications for the unit being serviced.
Refrigerant type
R404A
Amount
12.84 ounces
High design pressure
397 psig
Low design pressure
175 psig
Refrigerant type
R404A
Amount
7.05 ounces
High design pressure
397 psig
Low design pressure
175 psig
Refrigerant type
R404A
Amount
16.68 ounces
High design pressure
397 psig
Low design pressure
175 psig
Numeric Code (Alarm) Appears on Display
CFB2 and CFB3 with temperature display only. See list
below to determine possible problem.
Error
Code
Problem
Remedy
A1
Temperature probe
for bowl 1
disconnected
Call for service
A2
Bowl 1 too hot or
temperature probe
shorted
See "Check for Proper
Ventilation". If
ventilation is OK, call
for service..
A3
Temperature probe
for bowl 2
disconnected
Call for service
A4
Bowl 2 too hot or
temperature probe
shorted
See "Check for Proper
Ventilation". If
ventilation is OK, call
for service.
A5
Temperature probe
for bowl 3 (CFB3
only) disconnected
Call for service
A6
Bowl 3 (CFB3 only)
too hot or tempera-
ture probe shorted
See "Check for Proper
Ventilation". If
ventilation is OK, call
for service.
Check for Proper Ventilation:
1. The unit will not function properly if there is not
sufficient air space (4 inches minimum on back and
sides).
2.
Make sure that the filter (CFB2 and CFB3 only) is
clean and that all ventilation grills are not blocked or
dirty. See the CLEANING section.
3. Make sure that the unit is not close to sources of
heat that could affect proper operation (heaters,
cooking grills, etc.).