background image

User

Manual

Household

Softener

M

U

Summary of Contents for Rider

Page 1: ...User Manual Household Softener MU ...

Page 2: ......

Page 3: ...UNPACKAGING AND CONTENTS VERIFICATION 5 WARNINGS 6 SYSTEM INSTALLATION 7 START UP 8 MAINTENANCE SANITIZING 9 TROUBLESHOOTING GUIDE 10 MAINTENANCE MANUAL 11 EQUIPMENT INSTALLATION AND INITIAL OPERATION REGISTRATION SHEET TECHNICIAN 12 GUARANTEE CERTIFICATE 4 5 5 9 10 11 12 15 17 20 22 24 25 ...

Page 4: ... ENG ELECTRONIC TIMER Allows to control all parameters REGENERATIONS Delayed or immediate programming MIXING VALVE Allows to regulate the residual hardnes INTEGRATED BY PASS Allows to isolate the system from installation TRANSFORMER Outside KEEP THIS MANUAL THAT INCLUDES THE SERVICE BOOK AND THE GUARANTEE SECTION IT WILL PROVIDE YOU A BETTER POST SALE SERVICE ...

Page 5: ...s of soap The precipitation of hard minerals build a layer on cook 1 PRESENTATION The water treatment equipment that you have bought is a softener of last generation with one of the most advan ced control heads in the market This is a system which combines the properties and ad vantages of the classic Denver with a more efficient water and salt consumption thus contributing both to the pro tection...

Page 6: ... produ cing this way an ionic exchange inside the resin bed The treated water is collected by the distributor and dri ven through the inner tube through the vessel till the mul tiway valve It is sent with the out connection till the main water pipe for consumption In this point the system has a counter for treated water to be contabilized 2 3 Regeneration of the system The quantity of calcium and ...

Page 7: ...ertain level of hardness leakage High sodium concentration on water to be treated It may interfere in the exchange process Excessive flow rates Since there is not enough contact time some of the hard ness may not be retained by the resin 2 7 Residual hardness Depending on the final use of treated water it may be necessary to obtain fully softened water or on the contra ry it may be desirable to le...

Page 8: ...d as a guideline to know the increase on sodium concentration in treated water de pending on feed water hardness Initial hardness in water ºHF 10 15 25 30 35 40 45 50 60 Sodium added by the water softener mgNa litre 43 65 108 130 152 173 195 217 260 ...

Page 9: ... Exchangecapacity Caudalmínimo Rangodetemperaturas Rangodepresiones Pressurerating Electricalconnection Ratedelectricalpower Protectionclass Dimensions HeightA WidthB DepthC 4 35ºC 2 5 8 bar 220V 50Hz 24VAC 4W TIPO III RIDER 795238 25litres 9x35 1 0m3 h 1 5m3 h 120ºHF 1 5KgSal 96ºHFxm3 3 0KgSal 141ºHFxm3 6 25KgSal 175ºHFxm3 8bar 1100mm 360mm 530mm 0 1m3 h A C B System RIDER HIGH efficiency 96ºHFxm...

Page 10: ...nel Packaging and protection including a presurized air balloon to avoid the vessel movements Please read carefully this manual before starting insta lation The air balloon has to me removed before procee ding the system installation The packaging material can be recycled and must be thrown away in the suitable recycling bins or to be de livered to the specific centre for the collection of waste m...

Page 11: ...e RIDER series water treatment systems ARE NOT WATER PURIFIERS Its aim is to remove the hardness from water leaving a softened and treated water which will prevent all problems associ ated with hard water Should the water to be treated not come from a public water supply that is from an unknown source a physical chemical and bacterial anal ysis of the water shall be necessary with the aim of ensur...

Page 12: ... or if you think that it is not working properly contact your distributor 5 3 Setting up and maintenance The system must be periodically sanitised See Section 8 for further information Maintenance should be carried out by qualified tech nicians who work under the appropriate hygienic con ditions For further information contact the technical service of your distributor 6 SYSTEM INSTALLATION RIDER i...

Page 13: ...a near floor drain point This point should be no higher than the drain fitting on the salt storage tank NOTE Drain hose should be installed in a proper way just to avoid that the water overflows and returns from the drain hose RECOMMENDED INSTALLATION 2 Close the main water supply valve near the well pump or water meter 3 Open all faucets to drain all water from the house pi pes NOTE Be sure not t...

Page 14: ...mming 1 Connect the provided transformer to the electrical connector at the back of the system The timer will show service position IMPORTANT After connecting the system can show fo llowing message This message indicates that the system is placing itself in service position If after two minutes this message is still in the display please contact your distributor 2 Press MENU key for three seconds ...

Page 15: ...to the power supply using the transformer included in the system 5 The program must be in service otherwise please check Section 6 3 6 Press the REGEN button for 3 seconds to start a rege neration After some minutes the system will move to the Backwash stage 7 Slowly open the water inlet valve to allow the entran ce of water inside the system At this point the inlet flow tact your distributor SYST...

Page 16: ...y key 14 The softener will start to suction water from the tank brining position Check that the softener suctions water from the tank 15 Cancel the remaining stages of the regeneration 16 Put the by pass in service position and check that the treated water has been correctly softened see Section 7 3 17 Fill the tank with salt 18 The system is ready to work Start up process is fini shed WARNING Exc...

Page 17: ...idge and emp ty space forms between the water and the salt Then the salt will not be dissolved in the water to make brine and without brine the resin bed does not regenerate and you will get hard water If the storage tank is full of salt it is hard to tell if you have a salt bridge because salt is loose on top but the bridge is under it Take a tool or a broom handle for instance and hold it next t...

Page 18: ...kind of iron and other remaining metals that represent a contamination and at at the same time it will remove all possible incrustations in the inner pas sages of the valve NOTE Follow carefully the instructions of the use of the product stated out on the label of the same The maintenance and sanitizing of the system should be carried out by a specialized technician qualified in hygie nic conditio...

Page 19: ...Español 19 User Manual ...

Page 20: ...2 Revise the timer 3 Substitute the resin 4 Fill the storage with salt break the salt bridge 1 The minimum feed pressure should be of 2 5bar 2 Clean the brine line 3 Clean or replace the injector and the filter 4 Revise piston threads and separators 1 Please contact the distributor 2 Revise aspiration 3 Revise back flow 1 Check for loss of power and correct 2 Keep the brine tank full of salt 3 Rev...

Page 21: ...Español 21 User Manual NOTES ...

Page 22: ...IENTO COMPLETO REPARACIÓN HIGIENIZACIÓN OTROS TIPO DE SERVICIO FECHA NOMBRE FIRMA Y SELLO DEL TÉCNICO AUTORIZADO MANTENIMIENTO COMPLETO REPARACIÓN HIGIENIZACIÓN OTROS PUESTA EN MARCHA TÉCNICO SELLO TÉCNICO ORDINARIA EXTRAORDINARIA GARANTÍA ORDINARIA EXTRAORDINARIA GARANTÍA SELLO TÉCNICO ORDINARIA EXTRAORDINARIA GARANTÍA SELLO TÉCNICO ORDINARIA EXTRAORDINARIA GARANTÍA SELLO TÉCNICO ORDINARIA EXTRAO...

Page 23: ...IÓN HIGIENIZACIÓN OTROS TIPO DE SERVICIO FECHA NOMBRE FIRMA Y SELLO DEL TÉCNICO AUTORIZADO MANTENIMIENTO COMPLETO REPARACIÓN HIGIENIZACIÓN OTROS PUESTA EN MARCHA TÉCNICO SELLO TÉCNICO ORDINARIA EXTRAORDINARIA GARANTÍA ORDINARIA EXTRAORDINARIA GARANTÍA SELLO TÉCNICO ORDINARIA EXTRAORDINARIA GARANTÍA SELLO TÉCNICO ORDINARIA EXTRAORDINARIA GARANTÍA SELLO TÉCNICO ORDINARIA EXTRAORDINARIA GARANTÍA SELL...

Page 24: ...m bar INSTALLATION PROCESS CONTROL Assembly of pre filter Installation of isolation by pass Installation of overflow drain Proper installation of drain Start up according to the protocol Verification of brine suction tank filling Verification of connectors Watertightness of pressurised system Inlet hardness measuring Programing of the system Outlet hardness measuring Adjustment of residual hardnes...

Page 25: ...Español 25 User Manual 12 GUARANTEE CERTIFICATE ...

Page 26: ...IENTO COMPLETO REPARACIÓN HIGIENIZACIÓN OTROS TIPO DE SERVICIO FECHA NOMBRE FIRMA Y SELLO DEL TÉCNICO AUTORIZADO MANTENIMIENTO COMPLETO REPARACIÓN HIGIENIZACIÓN OTROS PUESTA EN MARCHA TÉCNICO SELLO TÉCNICO ORDINARIA EXTRAORDINARIA GARANTÍA ORDINARIA EXTRAORDINARIA GARANTÍA SELLO TÉCNICO ORDINARIA EXTRAORDINARIA GARANTÍA SELLO TÉCNICO ORDINARIA EXTRAORDINARIA GARANTÍA SELLO TÉCNICO ORDINARIA EXTRAO...

Page 27: ...Español 27 User Manual NOTES ...

Page 28: ...MUDENVER 2016 MU ...

Reviews: