Wireless Adapter (WA100-PM)
Securing Low Voltage Wires
1. Make sure the unit is NOT powered.
2. Cut the unused low voltage wires approximately five
inches from where they exit the WA100-PM body.
3. Isolate the end of each wire using a wire nut, shrink
tubing, or equivalent.
4. Wrap the unused low voltage wires around the side of
the adapter in a bunch, and secure them in place using a
white or clear cable tie.
Trimming and Dressing
When the wiring connections have been decided and extra (unused) wires identified, secure the unused wires to keep
them neat, out of the way, and protected against shorting or interference with other components, wiring, or devices.
It is best to trim unused wires to about 5 inches in length, isolate them using a wire nut or equivalent, then bundle and
bind them close to the adapter’s body. Be sure that unused Red and Violet output wires are completely isolated from all
other wires. Unused line voltage wires must be securely isolated and housed inside a junction box, or other approved
electrical enclosure.
Line Voltage
Wires
RED 14AWG
Switched load
J-Box or
Equivalent
Low Voltage Wires
WHITE 18AWG Neutral
Hot 120/230/277VAC
BLACK 14AWG
Cap unused wires
RED: 24VDC power output
VIOLET: 0-10V output
Tie Wrap (or equiv.)
Fig. 18: Secure unused wires
20