26
min
300mm
[11.81 in.
]
A
B
C
ø 150mm
[5.91 in.]
Fig. 10
MADE IN ITALY
Mod. DN435/2D
− C5−CP
VOLT
AC
3
− 400−50Hz − IPX3
KW
11
,
58
2020
S/N DN4352DC5CP 20031302
Fig. 11
Voltage
Installation
Serial number plate reading
The serial number is on the right hand side of the appliance.
It provides important technical information that is vital in case
of a request for maintenance or repair of the appliance: please
do not remove, damage or modify it.
Smoke extraction
Fig. 11
The oven is fitted with an adjustable exhaust in the top to get
rid of the steam from the cooking chamber.
This steam, together with the one from the door during the
work phases,
must be conveyed outside
in one of the
following ways:
•
A
through a
hood supplied by the Manufacturer
that
ensures perfect compatibility with the oven. For correct
assembly and fixing to the oven, see the sheet attached to it; the
evacuation flue must be for the exclusive use of the appliance,
comply with current regulations and have a diameter that allows
the passage of a
150 mm
[Ø5,91 in.]
evacuation pipe which
corresponds to the diameter of the tube to be mounted on the
hood (not supplied).
•
B
tthrough a
hood supplied by the user
, of suitable ca-
pacity, placed at minimum 300 mm [11.81in] from the
oven;
•
C
through an adequate
extraction system
supplied by
the user: in this case a draught switch must be installed
between the extractor and the oven chimney (the extractor
and switch are not supplied by the Manufacturer). In this type
of installation, the fumes resulting from the opening of the
door will not be extracted.
Model
Absorption
Year of production
Serial number
extraction
system
draught
switch