background image

Summary of Contents for 49-90331

Page 1: ... combustion from being blown into the room Service information and a wiring diagram are located in the dryer access panel TOOLS NEEDED Slipjoint pliers Phillips head and flat blade screwdrivers Ratchet with 3 8 socket Carpenter s level Adjustable wrenches Pipe thread sealer CONTENTS Installation Procedure page 2 Plumbing Information page S Electrical Information page 5 Gas Information page 6 Exhau...

Page 2: ... Untape and open washer lid Remove a foam tub blocking pad b foam shipping blocks from rear of unit c tape from druer door d foam dryer support pads e inlet hoses f From the back of the washer remove the wire shipping clips securing the drain hose Plastic clamps secure the drain hose to the right side of the washer backsheet These clamps form a standpipe to prevent water siphoning DO NOT REMOVETHE...

Page 3: ...UMBING FACILITIES CAUTION Be sure water supplg lines have been thoroughlg flushed to remove particles that might clog the washer filter screens r_ Check inlet hoses to insure the rubber washers are installed in each end If your laundry center has the hoses attached to the water valve proceed to Step 3A Carefully connect the inlet hoses to the water valve on the left side of the washer cabinet tigh...

Page 4: ...ould exist CHECKING APPLIANCE OPERATION r_ Make sure packing shipping are all and materials removed including the washer shipping bolt and plastic spacer block Make sure the drain hose is properly routed not coiled or kinked r e Hake sure water inlet hoses are connected HOT to HOT and tightened securely without kinks Turn on water faucets and check for leaks Tape all joints to make sure exhaust du...

Page 5: ...ANDPIPE DIAMETER The standpipe diameter must be 1 minimum There MUSTbe an air gap around the drain hose in the stundpipe A snug fit cun cuuse u siphoning uction SIPHONBREAKKIT For u drain fucilit9 less than 33 high the hose coupling and clumps provided in the machine must be used and in addition u siphon breuk MUST be instulled on the buck of the machine Use Siphon Break Kit WH49X228 und FOLLOW IN...

Page 6: ...line The gas supply line must have a shut off valve preferably within six feet of the dryer A 1 8 NPTplugged tapping accessible for test gauge connection must be installed immediately upstream of the gas supply connection EXHAUST EXHAUST DUCT LENGTH INFORMATION The MAXIMUM ALLOWABLElength of the exhaust system depends upon the type of duct number of turns the type of exhaust hood wall cap and all ...

Page 7: ...8 4 Clamps 2 WX8X59 4 Aluminum Hood MOBILE HOME INSTALLATION Installation must conform to Manufactured Home Construction and Safetg Standard Title 24 CFR Part 32 80 The druer must be exhausted to the outside with the termination securelUfastened to the mobile home structure The exhaust MUSTNOTbe terminated beneath the mobile home The exhaust duct material MUSTNOTsupport combustion CONSIDERATION MU...

Page 8: ... department Installation and service must be performed bg a qualified installer a service agencg or the gas supplier MISCELLANEOUS REQUIREMENTS LOCATION The appliance must be installed on firm flooring to minimize vibration during spin cycles Concrete flooring is best but wood base is sufficient providing the floor support meets FHA standards The appliance should not be installed on rugs or expose...

Reviews: