Power Requirements
•
Voltage operating range:
105-130 VAC or 198-253 VAC
•
Frequency:
50/60 Hz
High voltage inside. Risk of electric shock.
Turn power OFF and unplug power cord from machine before cleaning.
Do not attempt repairs. Repairs must be made by authorized Cummins-Allison
personnel.
Customer must provide grounded power line protected by properly grounded
15-amp circuit breaker in compliance with applicable local electrical code.
Plug three-prong grounded plug (supplied) into properly grounded three-prong
outlet.
Read and understand all instructions before use.
Power Consumption at Nominal Voltage
•
Full load amps (FLA):
.5/1A
Improper voltage levels can cause equipment malfunction, damage electrical
components, and void warranty.
Provide separate circuit serving only this device to ensure proper operation.
Follow listed power requirements to ensure proper operation.
Provide power conditioning/stabilizing devices if necessary.
Power disruptions and fluctuations causing input voltage other than listed in power requirements
can lead to improper operation of this device, damage to electrical components, and failure. Such
occurrences are not covered under the machine warranty or preventative maintenance agreement for this
device. Power conditioning/stabilizing devices are available for purchase from Cummins-Allison Corp.
Laser Specifications
•
Type:
Laser barcode scanner
•
Output wavelength:
650 nM nominal
•
Safety class:
CDRH Class II, 1.0 mW max.
Laser light present in hand-held barcode gun if installed.
Do not stare into laser beam.
Cummins-Allison Corp. has endeavored to make the content of this document accurate and complete, but this information is subject to correction or
change without prior notice.
All trademarks remain the property of their respective owners.