Part No. 4801-5307 Rev 2-15
Evolution 3000 and 3001
34 of 70
NOTE: Highlight and press ENTER to
bring up details on each stage.
**ON/OFF STAGES** ((1)Target = 73.0°)
(2)# (3)SENSORS (4)MODE (5)ON (6)OFF (7)TIMER
1
-------1 Feed 76 74 None
2
Light Ramp
3
-----321 Cstir 76 74 Min 2
4
-------1 Cneg 76 74 Min 1
5
------2- CNeg 77 75 None
6
-----3-- CNeg 78 76 None
7
------2- CNeg 79 77 None
8
-------1 CNeg 80 78 None
9
-------1 CNeg 81 79 None
7.8
ON/OFF Stages
You must select the set of stages you
want to set or edit. NOTE: When
programming stages you are allowed to
edit the settings from the main screen.
You are also allowed to go into each
stage and see a detailed screen. To do
this have a stage number highlighted
and then press enter.
(1)Target
– Displays the current set
Target Temperature.
(2) Stage # -
Stage Numbers.
(3) Sensors –
The sensors which may be
used to control the ON or OFF
point of a stage
.
Sensors 1 thru
8 may be selected or unselected
for each stage. The specific
stage will operate from the
selected sensor/sensors.
Active sensors will be indicated by a number starting with #1 from right to left. Inactive sensors
will be indicated by a - or hyphen. When "outside-" is displayed, the outside sensor is active. To
use sensors 1,2 and 3, "-----321" should be displayed.
(4) Mode –
This mode column will indicate how the stage is Programmed to operate.
(OFF) Disables stage from operating during automatic operation.
(Heat) Heat Mode: This method of heating only operates when the curtains are in the closed
position and the operating sensor is below the on temperature.
(CSTIR) Cool Stir Mode: This mode setting allows the cool stage to run whether the main curtain
is open or closed.
(CNEG) Cool Negative: Method of ventilation where air is drawn out of the building by fans,
creating a negative static pressure which draws air into the house from all openings at a
even pace. Will not operate in Tunnel or Nat.
(CNEGT) Cool Negative Tunnel: A combination of the Cool Negative and the Cool Tunnel
Modes.
(CTUN) Cool Tunnel: Only operate during Tunnel operation with one exception being set as a
minimum ventilation timer which will allow the stage to operate on a timer only, in
minimum or power ventilation.
(LIGHT) The LIGHT Mode: See Section 7.12.
(FEED) The FEED mode: See Section 7.11.
(CEVAP) Cool Evaporative mode: See Section 7.10.6
(CHEAT) Cooler Heat mode: Heat stage for the Cooler.
(CCOOL) Cooler Cool mode: Cool stage for the Cooler.
(CHUM) Cooler Humidity mode: Humidifier for the Cooler.
(5&6) ON/OFF –
The ON column will indicate the current setting for the onpoint temperature of the stage.
Set this to the temperature you would like for the stage to come on at. The OFF column will
indicate the current setting for the offpoint temperature of the stage. Set this to the temperature you
would like for the stage to turn off at.
(7) TIMER –
None, Min1, Min2, Var, Cool, OPT1-OPT8 This Timer column will indicate what type of
timer you want the stage to operate from. If the stage doesn't need a timer then you must have this
setting to none.