Part No. 4801-5307 Rev 2-15
Evolution 3000 and 3001
16 of 70
.
.
.
.
.
.
.
.
.
.
.
.
.
.
(1)# (2)STATUS
(3)MODE (4)RTEMP (5)ON (6)OFF (7)TIME
TUN
OFF
CTUN
79.4°
85°
80°
1
On
Light
Ramp
2
On
Cstir
79.6°
76°
95°
None
.
.
.
.
.
.
.
-----------
(8)TARGET
70°
---------
.
.
.
.
.
.
.
16
On
Cstir
79.6°
76°
95°
Min1
(1)# (2)STATUS
(3)MODE
(4)RTEMP (5)ON (6)OFF (7)TIME
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
U1
On
NAT CLOSE 73.0°
72.0° CLOSED: NO
U2
On
N&T CLOSE 73.0°
72.0° CLOSED: NO
Min1
U1
Off
NAT OPEN
73.0°
74.0° CLOSED: NO
U2
Off
N&T OPEN
73.0°
74.0° CLOSED: NO
.
.
.
.
.
.
.
.
.
.
.
.
.
.
6.4.2
On/Off Stages
The On/Off stages are used for devices that do not need a variable speed capability. This portion of the
Stage Conditions screen shows how the On/Off Stages and are set.
(1) # -
Identifies the On\Off stage number
or Tunnel and lists them in the order
of priority. Tunnel is not a stage like
the Stage Master and Vent Master.
This parameter is set in the tunnel
ventilation of Program Setup screen.
See
Section 7.7, Tunnel
Ventilation
.
(2) Status -
Indicates if the stage is currently
Timed, On, or Off.
(3) Mode -
This column indicates how the
stage is programmed. Any stage can
be set to any of these modes. The
available stage options are: Off,
Heat, CSTIR, CNEG, CNEGT,
CTUN, LIGHT, FEED or CEVAP.
(4) Rtemp -
The Rtemp column will indicate the
current temperature from which the stage is
operating.
(5) On –
The current temperature setting for the on
point temperature of the stage.
(6) Off -
The current temperature setting for the off
point temperature of the stage.
(7) Time -
This column indicates if a stage is on a
timer and shows the different timers you are
allowed to put a stage on. The timer options
are: None, Min1, Min2, Var, Cool, or Opt
xx.
(8) Target –
Target Temperature.
6.4.3
Natural Ventilation Stages
Natural Ventilation stages are used to open and close side curtains to allow natural ventilation.
(1) #-
The stage bank either U1 or U2.
(2) Status -
This column will indicate whether the machine is Off, Opening or Closing.
(3) Mode –
The mode column indicates how the machine will be operating. It will be a natural curtain
"NAT" or a natural and tunnel "N&T" machine(U2 only). OPEN or CLOSE will be shown beside
the mode to show whether the specific line refers to the Open or Close function.
(4) Rtemp –
The Rtemp column will indicate the current temperature the curtain machine is operating from.
(5) ON –
The temperature at which the stage operates.
(6) OFF and (7) TIME –
This column indicates if the machine is fully closed. When the machine is on the
closed auxiliary switch, this column will display “Yes”.