Part No. 4801-5307 Rev 2-15
Evolution 3000 and 3001
10 of 70
** PASSWORD PROTECTED **
You must enter the current controller
Password to continue.
Press the ENTER button to proceed.
Password: XXXX
5.5
Status Display
The following is an example of Main Display screen displaying the standard Target Conditions status
screen. The Main Display screen displays both status and programming screens.
5.6
Stage Switch
The stage LED indicator lights when a stage is active. The stage switch is used to select Auto operation,
On, or Off. If switch is in Auto position, the stage operation is controlled by the controller. That is, the
stage may turn on and off according to settings selected from the Main Display screen. If switch is in the
On position, a stage is On continuously. If switch is in the Off position, a stage is Off with the exception of
Back-Up conditions.
The white space is used to affix a label indicating stage function (i.e. brooder, fan, light, cool, etc.)
NOTE: Stages 1-16 are marked on Main panel. For optional stages 17-64, use stick-on label to number
stages.
5.7
Locks
A lock feature has been included for additional
security to the Evolution 3000 and 3001 settings
with software versions V0.16 and higher. This
feature locks the Program Setup screens to
prevent changes. Locked screens are noted by a
lock symbol ( ) in the upper right of the
screen. The Target Conditions and Minimum
Vent screens are not lockable. When the lock
feature is disabled ( ), all screens will show
unlocked until the password is changed. See
Section 7.13.
NOTE: The Diagnostics screen can only be unlocked using the HHI Service Code; Contact your local
dealer for assistance.
1
1
Stage number
(Use labels to denote
stages 17-64)
ON, OFF, AUTO
Switch positions
Stick Icon label onto
white area or use for
notation
LED Indicator (lights
when stage is ON)
Icon labels are provided to
affix to white area of stage
control. Icon symbols are
shown at right.
Heater
Negative Fan
Light
Stir Fa n
Neg./Tun.
Feed
Evap. Cooling
Tunnel Fan
The Scroll Symbol is a
flashing down arrow (
) that
indicates more text outside
of display screen. Use
up/down editor arrow keys
to scroll text.
The Link Symbol (
) is a right
pointing arrow and indicates a
link to another display screen.
To change
parameter:
Select parameter
using editor
arrow keys. Use
+ and - keys to
change value.
(1)Target Temp =
77.5°
(2)Ramping:
On
(3)Target Press =
0.04 wc
(4)Ramping:
Off
(5)Tunnel Press =
0.00 wc
(6)Target Humidity < 60%
(7)Light Schedule
(8)Feed
Schedule
77.5°
NOTE: If Optimum Mode is turned On, the Target Conditions screen
will have differences from the standard screen shown above.