WTR III TRACK VERSION ONLY - HOW TO INSTALL THE ADAPTERS - The WTR III 15” track
configuration is shown in this procedure. All other configurations are assembled in a similar
fashion, but with different parts that are provided in the Configuration Matrix in this manual.
Remove the track assemblies from the unit (refer to the instructions provided in the previous
INSTALLING THE TRACK MODULES procedure. The removal process is achieved by performing the
opposite steps of this installation procedure). Remove the cable tie from the motor transmission module.
Shaft Extenders:
NOTE: For configurations 8” and larger, install shaft extender P/N TX336- and applicable dash number
that corresponds with the pipe size to be inspected (refer to the
Configuration Matrix
in this manual).
Connect Strip:
NOTE: For configurations 15” and larger, install the TX337- and applicable dash number that corresponds
with the pipe size to be inspected (refer to the
Configuration Matrix
in this manual).
Cable:
NOTE: For configurations involving 18” and larger pipe, it will be necessary to change the TX342 cable.
TX342 must be removed and TX342-1 must be installed. Refer to the CABLE INSTALLATION AND
REMOVAL procedure in this manual for detailed instructions.
1. Install the adapter(s) on the right side.
1
ADAPTING THE WTR III TO DIFFERENT PIPE CONFIGURATIONS
-TRACKS