41
01/2005 - Art. Nr. 13 010 553B
daPa
mbar
kW
40
0
2
4
6
8
10
5
15
25
35
45
0
0,2
0,4
0,6
0,8
1
NC4 GX107/8
Main components
·
Control and safety unit:
SG 1xx
·
Flame detection:
Ionization probe.
·
Electric fan motor:
85W single-phase 230V,50Hz 2840min
-1
capacitor 3µF
·
Ventilation turbine:
NC4/6:
Ø133 x 42
NC9:
Ø133 x 62
·
Ignition transformer:
1 x 11kV
·
Air pressure switch:
LGW 3 C3
·
Blast tube:
NC4/6:
Ø58/65/80 x 193
NC9:
Ø68/78/90 x 193
·
Multibloc valve with pressure
regulator and filter:
NC4/6:
CG10R70-D1T5BWZ
NC9:
CG15R03-D2W5CWZ
General information
Technical data
Burner power kW
NC4
NC6
NC9
min
max
min
max
min
max
Burner
Generator
Actual rated gas flow
at 15°C and 1013 mbar
- Natural group H
m
3
/h
Hi = 9,45 kWh/m
3
- Natural group L
m
3
/h
Hi = 8,13 kWh/m
3
- Propane P
m
3
/h
Hi = 24,44 kWh/m
3
Density in kg/m
3
= 1,98
14.5
13.3
1.53
1.78
0.59
40
36.8
4.23
4.92
1.64
40
36.8
4.23
4.92
1.64
55
50.6
5.82
6.77
2.25
45
41.4
4.76
5.53
1.84
90
83
9.52
11
3.70
EN
daPa
mbar
kW
45
0
2
4
6
8
10
40
50
60
70
80
90
100
0
0,2
0,4
0,6
0,8
1
NC9 GX107/8
daPa
mbar
kW
0
2
4
6
8
10
35
40
45
50
55
60
0
0,2
0,4
0,6
0,8
1
NC6 GX107/8
Summary of Contents for 13 009 306
Page 14: ...01 2005 Art Nr 13 010 553B 14 ...
Page 52: ...01 2005 Art Nr 13 010 553B 52 ...
Page 58: ...01 2005 Art Nr 13 010 553B 58 ...
Page 59: ...59 01 2005 Art Nr 13 010 553B ...