10
Installation – Settings
DIP 8: Autoconnect
NB: In order for this function to work, DIP 9 must be ON. Fifteen minutes
after turning the cooker off, the Cooker Guard will automatically be
reset and turn the power back on. On a cooker with rotary switches,
all the rings and oven must be turned off before the Cooker Guard will
reset itself automatically.
If this function is not activated or to reset the Cooker Guard manually,
press the control button on the sensor (or external switch panel,
optional extra).
DIP 9: Current measurement
When current measurement is ON, the Cooker Guard will only give an
alarm when the cooker is in use. This includes all types of alarm signal,
including low battery.
NB: We recommend that you do not turn off current measurement,
as this will reduce battery life considerably.
DIP 9
Current measurement
Standard
OFF
Current measurement off
ON
DIP 8
Autoconnect
Standard
OFF
Autoconnect off
ON
DIP 5, 6 and 7: Timer function
The countdown starts when the cooker is turned on. When 5 minutes of
the set time are left, the Cooker Guard beeps once every 15 seconds for
5 minutes. Pressing the control button restarts the countdown.
DIP 5 DIP 6 DIP 7 Minutes (extended)
Standard
ON
OFF
OFF
15 (2 h)
ON
ON
OFF
30 (2 h)
ON
ON
ON
45 (2 h)
OFF
ON
ON
60 (2 h)
OFF
OFF
ON
90 (2 h)
OFF
ON
OFF
120 (12 h)
ON
OFF
ON
360 (12 h)
OFF
OFF
OFF
Off