background image

11

Installation – Calibration and function test 

Function test

There are two different function tests:   1 = On/Off test    2 = Current test.     

To activate the function test:
1.  Remove the SENSOR cover and set DIP switch 0 to ON
2.  Put the cover back on temporarily to stop the batteries falling out.

To change between the two function tests, hold the control button on 
the  SENSOR in for five seconds. 
The sensor acknowledges with one or two beeps to indicate the test type.

Calibrating electricity consumption

If the yellow LED on the SOCKET comes on continuously when the hob 
is OFF and does not disappear when the control button on the sensor is 
pressed, the cooker’s standby current is higher than the Cooker Guard’s 
preprogrammed standby level.

In this case the level can be recalibrated to actual electricity 
consumption by:
1.  Holding the SOCKET’s control button in until the red and green LEDs 

flash – then release the button within two seconds. 

2.  The green LED flashes three times to acknowledge the change.

NB: We strongly recommend measuring the hob’s electricity 
consumption in standby BEFORE doing this calibration. High electricity 
consumption could be caused by a fault in the hob. Incorrect calibration 
the case of high electricity consumption can result in the Cooker Guard 
never starting or not working as intended.

1 beep

On/Off test

The sensor acts as an 
ON/OFF switch. 

Pressing the control button 
switches between turning the 
power to the cooker ON/OFF. 

The light on the SENSOR comes 
on when the cooker socket is on 
(sending power to the cooker).

2 beeps

Current test

Indicates electricity consumption for 
the hob.

Following activation turn the hob on ON. 
A few seconds later the red LED on the 
SENSOR should come on continuously 
and the green and yellow LEDs on the 
SOCKET should light up.

Now turn the hob off. The red LED on the 
SENSOR goes out and only the GREEN 
LED on the SOCKET should be on.

NB: May only be carried out by 

an authorised electrician.

When you have performed the function test(s), remember to set DIP 
switch 0 to OFF.

10

Installation – Settings

DIP 8: Autoconnect

NB: In order for this function to work, DIP 9 must be ON. Fifteen minutes 
after turning the cooker off, the Cooker Guard will automatically be 
reset and turn the power back on. On a cooker with rotary switches, 
all the rings and oven must be turned off before the Cooker Guard will 
reset itself automatically.
If this function is not activated or to reset the Cooker Guard manually, 
press the control button on the sensor (or external switch panel, 
optional extra).

DIP 9: Current measurement

When current measurement is ON, the Cooker Guard will only give an 
alarm when the cooker is in use. This includes all types of alarm signal, 
including low battery. 

NB: We recommend that you do not turn off current measurement, 
as this will reduce battery life considerably.

DIP 9

Current measurement

Standard

OFF

Current measurement off

ON

DIP 8

Autoconnect

Standard

OFF

Autoconnect off

ON

DIP 5, 6 and 7: Timer function

The countdown starts when the cooker is turned on. When 5 minutes of 
the set time are left, the Cooker Guard beeps once every 15 seconds for 
5 minutes. Pressing the control button restarts the countdown.

DIP 5  DIP 6 DIP 7 Minutes (extended)

Standard

ON

OFF

OFF

15 (2 h)

ON

ON

OFF

30 (2 h)

ON

ON

ON

45 (2 h)

OFF

ON

ON

60 (2 h)

OFF

OFF

ON

90 (2 h)

OFF

ON

OFF

120 (12 h)

ON

OFF

ON

360 (12 h)

OFF

OFF

OFF

Off

Summary of Contents for 6251650

Page 1: ...Installation instructions User instructions SAVE THESE INSTRUCTIONS mKomfy 1 8 16R mKomfy 1 8 16R Plug Play El nr 6251650 P P 6251655 ...

Page 2: ...ardboard newspaper or if such materials catch fire near to the cooker hob The product assumes normal care in the use of the cooker and associated cookware In normal use the cooker should be kept under frequent observation even if safety equipment such as mKomfy is installed Lots of smoke will be produced before the device is triggered so additional equipment such as Strømkutt could help to make th...

Page 3: ...curity function will be activated and beep 5 times in 5 seconds before turning the cooker off Replace the sensor in the wall bracket and press the control button to continue using the cooker Optional timer function see page 10 for activation When the Cooker Guard detects that the cooker has been turned on it can start a built in timer countdown clock When the timer reaches zero the cooker is turne...

Page 4: ...nds The sensor beeps twice to confirm that the cooking time has been extended When the time expires or the cooker has been turned off for at least 2 minutes the countdown is reset to the standard time To cancel the extended cooking time hold the control button in for 10 seconds The sensor beeps once to confirm Light Control button Reset alarm Extend cooking time Reset cut out Temperature sensor Cl...

Page 5: ... and sound signals in the course of 5 seconds Cause Anti tamper function detects that sensor has been removed from bracket Action Replace sensor in bracket and press control button Alarm signal Two 2 light and sound signals every 5 minutes Cause Battery change necessary Action Change batteries NB Make sure you have new batteries to hand first 3 x AA Alarm signal Three 3 light and sound signals eve...

Page 6: ...t batteries in the sensor 3 There are 4 beeps the blue LED on the socket flashes and the socket turns off 4 Release the control button on the sensor The sensor and socket are now paired Status LEDs Green lights up when socket is ON Blue flashes when data is received from paired units e g sensor Blue Green flash alternately 1 minute afteremergencymode is activated and continues toflashwhilethe prod...

Page 7: ...crew must be used in the centre of the bracket foot 3 Press the control button on the sensor once A short beep confirms that the sensor is in communication with the socket and working If there is no beep check that the sensor has been correctly mounted in the fixing bracket anti tamper function 4 Make sure that only the green LED on the socket lights up when the cooker is connected and turned off ...

Page 8: ...e sensor off the wall 2 Remove the back cover Fylls i av DIP Function Standard Set to DIP 1 Sound ON DIP 2 Light ON DIP 3 Installation height OFF DIP 4 Installation height OFF DIP 5 Timer OFF DIP 6 Timer OFF DIP 7 Timer OFF DIP 8 Autoconnect ON DIP 9 Current measurement ON DIP 0 Test mode OFF List of DIP switch functions You will find more information on the individual functions and settings on th...

Page 9: ...false alarms as the sensor also measures the heat outside the actual ring Allowance can be made for this by increasing the alarm threshold for the smallest rings NB Increasing the alarm thresholds will reduce safety because in certain cases the Cooker Guard will not differentiate between the smallest plates and radiant residual heat Nor will the Cooker Guard comply with EN50615 in some cases when ...

Page 10: ...ooker Guard will only give an alarm when the cooker is in use This includes all types of alarm signal including low battery NB We recommend that you do not turn off current measurement as this will reduce battery life considerably DIP 9 Current measurement Standard OFF Current measurement off ON DIP 8 Autoconnect Standard OFF Autoconnect off ON DIP 5 6 and 7 Timer function The countdown starts whe...

Page 11: ... within two seconds 2 The green LED flashes three times to acknowledge the change NB We strongly recommend measuring the hob s electricity consumption in standby BEFORE doing this calibration High electricity consumption could be caused by a fault in the hob Incorrect calibration the case of high electricity consumption can result in the Cooker Guard never starting or not working as intended 1 bee...

Page 12: ...er Guard mKomfy 1 8 16R Operating voltage 230 VAC 10 Max load 16A Battery 3 x AA LR06 Battery life Up to 5 years RF 868 100 MHz 5 dBm Cooker guard type Category B Manufacturer CTM Lyng AS www ctmlyng com tel 47 72831611 Thank you for choosing ...

Reviews: