background image

7

Installation - Sensor

2. Fitting the sensor

NB:

 If testing the sensor prior to mounting, the sensor must be placed in the fixing bracket 

so as not to activate the anti-tamper function. mKomfy 1.8 sensor f.o.m. snr: 2024-000001 
has a new fixing bracket (with lug) which is not compatible with the previous version.

1.  Remove the battery cover and fit batteries (3 x AA). 

2 beeps = battery OK. 

2.  Tear off the red protective film on the bracket.

Mount the sensor on a flat, clean surface on the wall above the 
centre of the cooker at a height of 45-55 cm, see figure 2. For other 
installation heights, see page 9.

NB: If the material on the wall surface is unsuitable for mounting with 

tape, a screw must be used in the centre of the bracket foot.

3.  Press the control button on the sensor once. A short beep confirms 

that the sensor is in communication with the socket and working. 
If there is no beep, check that the sensor has been correctly mounted 
in the fixing bracket (anti-tamper function).

4.  Make sure that only the green LED on the socket lights up when the 

cooker is connected and turned off. If the yellow LED lights up, the 
cooker’s standby electricity consumption is higher than the standard 
setting. In this case the level in the mKomfy can be calibrated to the 
cooker’s actual electricity consumption, see pages 10 and 11.

*

*

45 til 70 cm

30 cm

60 cm

60 cm

30 cm

Senter komfyrvakt

Senter komfyr

figure 2

sensor height 45-75 cm for hobs <= 60 cm wide
sensor height 65-70 cm for hobs <= 90 cm wide

Centre of Cooker Guard

Centre of cooker

6

Installation – Socket

1. Fitting the socket (may 
only be carried out by 
authorised personnel)

1.  Connect and fit the 

socket.

2.  Connect the cooker 

plug to the Cooker 
Guard’s socket.

3.  Check that power 

is connected to the 
socket.

DO  NOT CONNECT!

If there is no radio communication from the sensor, the plug will shut off after 5 minutes. 

The sensor and socket are paired at the factory and ready to install.

If re-pairing is necessary:

Remove at least once battery from the sensor (you can get batteries ready for 
the sensor, but DO NOT fit them).

1. 

Give the Socket control button a quick press. Yellow LED flashes.

2.  Hold the control button on the sensor in and fit batteries in the sensor.
3.  There are 4 beeps, the blue LED on the socket flashes and the socket 

turns off.

4.  Release the control button on the sensor.

The sensor and socket are now paired.

Status LEDs

Green

lights up   

when socket is ON

Blue   

flashes 

when data is received from paired units (e.g. sensor)

Blue + 
Green

flash  
alternately

1 minute after emergency mode* is activated, and continues 
to flash while the product is in emergency mode (12 hours).

Red   

flashes 

if socket overheats – socket is turned OFF

Red    


beeping

if there is an error, e.g. external switch paired before 
sensor

Yellow  lights up   

when cooker’s electricity consumption exceeds 1.2 A

**

Yellow    flashes  

in pairing mode

emergency mode = all safety functions deactivated. See page 5.

** 

1.2 A is the factory default. After calibration, the LED lights up when the new setting is 

exceeded (page 11)

Control button

Summary of Contents for 6251650

Page 1: ...Installation instructions User instructions SAVE THESE INSTRUCTIONS mKomfy 1 8 16R mKomfy 1 8 16R Plug Play El nr 6251650 P P 6251655 ...

Page 2: ...ardboard newspaper or if such materials catch fire near to the cooker hob The product assumes normal care in the use of the cooker and associated cookware In normal use the cooker should be kept under frequent observation even if safety equipment such as mKomfy is installed Lots of smoke will be produced before the device is triggered so additional equipment such as Strømkutt could help to make th...

Page 3: ...curity function will be activated and beep 5 times in 5 seconds before turning the cooker off Replace the sensor in the wall bracket and press the control button to continue using the cooker Optional timer function see page 10 for activation When the Cooker Guard detects that the cooker has been turned on it can start a built in timer countdown clock When the timer reaches zero the cooker is turne...

Page 4: ...nds The sensor beeps twice to confirm that the cooking time has been extended When the time expires or the cooker has been turned off for at least 2 minutes the countdown is reset to the standard time To cancel the extended cooking time hold the control button in for 10 seconds The sensor beeps once to confirm Light Control button Reset alarm Extend cooking time Reset cut out Temperature sensor Cl...

Page 5: ... and sound signals in the course of 5 seconds Cause Anti tamper function detects that sensor has been removed from bracket Action Replace sensor in bracket and press control button Alarm signal Two 2 light and sound signals every 5 minutes Cause Battery change necessary Action Change batteries NB Make sure you have new batteries to hand first 3 x AA Alarm signal Three 3 light and sound signals eve...

Page 6: ...t batteries in the sensor 3 There are 4 beeps the blue LED on the socket flashes and the socket turns off 4 Release the control button on the sensor The sensor and socket are now paired Status LEDs Green lights up when socket is ON Blue flashes when data is received from paired units e g sensor Blue Green flash alternately 1 minute afteremergencymode is activated and continues toflashwhilethe prod...

Page 7: ...crew must be used in the centre of the bracket foot 3 Press the control button on the sensor once A short beep confirms that the sensor is in communication with the socket and working If there is no beep check that the sensor has been correctly mounted in the fixing bracket anti tamper function 4 Make sure that only the green LED on the socket lights up when the cooker is connected and turned off ...

Page 8: ...e sensor off the wall 2 Remove the back cover Fylls i av DIP Function Standard Set to DIP 1 Sound ON DIP 2 Light ON DIP 3 Installation height OFF DIP 4 Installation height OFF DIP 5 Timer OFF DIP 6 Timer OFF DIP 7 Timer OFF DIP 8 Autoconnect ON DIP 9 Current measurement ON DIP 0 Test mode OFF List of DIP switch functions You will find more information on the individual functions and settings on th...

Page 9: ...false alarms as the sensor also measures the heat outside the actual ring Allowance can be made for this by increasing the alarm threshold for the smallest rings NB Increasing the alarm thresholds will reduce safety because in certain cases the Cooker Guard will not differentiate between the smallest plates and radiant residual heat Nor will the Cooker Guard comply with EN50615 in some cases when ...

Page 10: ...ooker Guard will only give an alarm when the cooker is in use This includes all types of alarm signal including low battery NB We recommend that you do not turn off current measurement as this will reduce battery life considerably DIP 9 Current measurement Standard OFF Current measurement off ON DIP 8 Autoconnect Standard OFF Autoconnect off ON DIP 5 6 and 7 Timer function The countdown starts whe...

Page 11: ... within two seconds 2 The green LED flashes three times to acknowledge the change NB We strongly recommend measuring the hob s electricity consumption in standby BEFORE doing this calibration High electricity consumption could be caused by a fault in the hob Incorrect calibration the case of high electricity consumption can result in the Cooker Guard never starting or not working as intended 1 bee...

Page 12: ...er Guard mKomfy 1 8 16R Operating voltage 230 VAC 10 Max load 16A Battery 3 x AA LR06 Battery life Up to 5 years RF 868 100 MHz 5 dBm Cooker guard type Category B Manufacturer CTM Lyng AS www ctmlyng com tel 47 72831611 Thank you for choosing ...

Reviews: